PENUMBRA, INC. PENUMBRA COIL 400; HCG, KRD Back to Search Results
Catalog Number 4004C0412
Medical Device Problem Code Failure to Advance (2524)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 11/07/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This device is available for return.A follow up mdr will be submitted upon completion of the device investigation.
 
Event or Problem Description
The patient was undergoing a coil embolization procedure in the left internal carotid artery (ica) using penumbra coil 400s (pc400s).During the procedure, while attempting to advance a pc400 into a px slim delivery microcatheter (px slim), the pc400 would not advance past the proximal end of the px slim; therefore, the pc400 was removed.The procedure was completed using a new pc400 and the same px slim.There was no report of an adverse effect to the patient.
 
Additional Manufacturer Narrative
Results: the pet lock was intact at the proximal end of the pusher assembly.The pusher assembly had a bend and kink approximately 5.0 cm and 57.0 cm from the proximal end.The stretch resistant (sr) wire within the embolization coil was fractured and the proximal constraint sphere was within the pusher assembly distal detachment tip (ddt).Conclusions: evaluation of the returned pc400 revealed a kinked pusher assembly.If the device is forcefully advanced against resistance, damage such as a kink may occur.The px slim used in the procedure was not returned for evaluation; therefore, the root cause of this resistance could not be determined.Further evaluation revealed a detached embolization coil due to sr wire fracture.This damage was not identified in the reported complaint and was likely incidental to the reported complaint.Penumbra coils are inspected during in-process inspection and during quality inspection after manufacturing.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PENUMBRA COIL 400
Common Device Name
HCG, KRD
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
MDR Report Key8189953
Report Number3005168196-2018-02489
Device Sequence Number16804445
Product Code HCG
UDI-Device Identifier00814548010847
UDI-Public00814548010847
Combination Product (Y/N)Y
Initial Reporter CountryGM
PMA/510(K) Number
K120330
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 11/23/2018
Report Date (Section F) 01/01/2005
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/01/2026
Device Catalogue Number4004C0412
Device Lot NumberF84454
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/27/2018
Was the Report Sent to FDA? Yes
Date Report to Manufacturer01/10/2005
Initial Date Received by Manufacturer 11/23/2018
Supplement Date Received by Manufacturer02/11/2019
Initial Report FDA Received Date12/21/2018
Supplement Report FDA Received Date02/25/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age66 YR
Date Report Sent to FDA01/01/2005
-
-