Catalog Number PXC141000
Medical Device Problem Code Insufficient Device Problem Information (3190)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 11/29/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
A review of the manufacturing records for the device verified that the lot met all pre-release specifications.Imaging evaluation results: ct images dated (b)(6) 2018 were received by gore from the facility and an imaging evaluation was performed.There appeared to be contrast outside of the implanted device indicative of an endoleak, but of indeterminate origin.Per the gore® excluder® aaa endoprosthesis instructions for use (ifu), adverse events that may occur and/or require intervention include, but are not limited to endoleak and aneurysm enlargement.Users are made aware of the risks associated with type ii endoleaks and are instructed to consider the risks and benefits discussed in the ifu for each patient before using the devices.
 
Event or Problem Description
On (b)(6) 2015, the patient was implanted with two gore® excluder® aaa endoprostheses.On (b)(6) 2018, a computed tomography (ct) scan reportedly revealed a suspected type ii endoleak contributing to aneurysm growth (amount not reported).On (b)(6) 2018, the patient underwent a secondary intervention procedure.An intra-operative angiograph revealed what was thought to be a type iii endoleak with a hole or disruption in the graft material.The physician elected to re-line both distal limbs with additional 14mm excluder® contralateral leg components.The patient tolerated the procedure.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AORTIC EXCLUDER AAA ENDOPROSTHESIS (LOW PERM)
Common Device Name
SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
Manufacturer (Section D)
W.L. GORE & ASSOCIATES
flagstaff AZ
MDR Report Key8196010
Report Number2953161-2018-00101
Device Sequence Number19311089
Product Code MIH
UDI-Device Identifier00733132609949
UDI-Public00733132609949
Combination Product (Y/N)N
Initial Reporter StateCO
Initial Reporter CountryUS
PMA/510(K) Number
P020004
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/29/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date06/30/2018
Device Catalogue NumberPXC141000
Device Lot Number14124373
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date12/26/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient Age81 YR
-
-