MENTOR TEXAS MENTOR CPX 2 BREAST TISSUE EXPANDER; EXPANDER, SKIN, INFLATABLE Back to Search Results
Catalog Number 3546112
Medical Device Problem Code Material Rupture (1546)
Health Effect - Clinical Code No Code Available (3191)
Date of Event 01/01/2012
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
At the time of this report, mentor has received no information regarding explantation or an expected explantation date.It is unknown at this time if the device will be made available for return.As a result, no product failure analysis can be conducted, and no determination of possible contributing factors can be made.As such, the investigation will be closed.If the complaint device is received in the future, the investigation will be reopened and conducted as appropriate.Since no lot number was provided, no device history record (dhr) review could be performed.(b)(4).
 
Event or Problem Description
It was reported that a female patient underwent breast reconstruction with a 350 cc mentor cpx 2 breast tissue expander.The expander was implanted after the patient went through a breast cancer surgery in 2012 and it was reported to have been defective from the beginning and also had leakage.It was also reported that the patient assumed it was perforated during surgery.At the time of this report, mentor has received no information regarding explantation or an expected explantation date.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MENTOR CPX 2 BREAST TISSUE EXPANDER
Common Device Name
EXPANDER, SKIN, INFLATABLE
Manufacturer (Section D)
MENTOR TEXAS
3041 skyway circle north
irving TX 75038
MDR Report Key8196710
Report Number1645337-2018-07560
Device Sequence Number295442
Product Code LCJ
UDI-Device Identifier00081317002192
UDI-Public00081317002192
Combination Product (Y/N)N
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source consumer,foreign
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 12/03/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number3546112
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 12/03/2018
Initial Report FDA Received Date12/26/2018
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-