The device was received, the investigation is in progress, no conclusion could be drawn at the time of filing this report.A device history record review has been requested.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Part 389.266, lot t952575: release to warehouse date: october 15, 2010.Manufacture site: tuttlingen.A review of the device history records showed that there were no issues at the time of manufacturing of this device and its sub components that would contribute to the complaint condition.No non-conformance reports (ncrs) were generated during the production of this device.Review of the device history record of tuttlingen showed that there were no issues at the time of manufacturing of this device that would contribute to the issue outlined in this complaint.A product investigation was completed: upon visual inspection the distal tip of the lower jaw is cracked/bent preventing the device from functioning as intended.The balance of the device is in fair condition.The received condition does agree with complaint description and is confirmed.The relevant dimensions were measured and found to be conforming.The relevant drawings were reviewed.No design or manufacturing defect or deficiency was observed during the investigation.A device history review, was performed for the returned instrument¿s lot number, and no non-conformance reports (ncrs), no material review reports (mrrs) or complaint-related issues were identified with the lot number which may have contributed to the complaint condition.Based on the available information a root cause could not be determined.During the investigation, no product design or manufacturing issues were observed that may have contributed to the complaint condition.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|