U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDTRONIC MEXICO ACHIEVE MAPPING CATHETER; CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC MEXICO ACHIEVE MAPPING CATHETER; CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING Back to Search Results
Model Number 990063-015
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Low Blood Pressure/ Hypotension (1914); Great Vessel Perforation (2152); Cardiac Perforation (2513); Pericardial Effusion (3271)
Date of Event 12/04/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
It was reported that during a cryo ablation procedure, after a freeze was delivered, and the balloon catheter was thawed and deflated, it was observed that the patient's blood pressure significantly dropped.Measures to improve the patient's blood pressure were initiated, and a pericardial effusion was observed via intracardiac ultrasound.Heparin was immediately stopped, and a heparin reversal medication was administered.A pericardiocentesis was then performed, which aspirated a significant amount of fluid.Aspiration from the pericardial drain was performed multiple times which improved the patient's blood pressure.Additionally, an anticoagulant was administered.The case was aborted, and the patient was under general anesthesia.The patient left the procedure area with still a pericardial drain in place.The patient was then scheduled for a surgical repair, and was transferred to the intensive care unit (icu) for observation.It was noted that the patient continued to be sedated and intubated post procedure.No further patient complications have been reported as a result of this event.
 
Additional Manufacturer Narrative
Product event summary: the data files were returned and analyzed.The data files showed ten applications were performed with balloon catheter 2af284, lot number 34419 without any issues on the date of the event.Clinical issues (pericardial effusion, hypotension, perforation and aborted under general anesthesia) occurred during the case.There is no indication that the adverse event was related to the performance of the reported mapping catheter.In conclusion, there is no indication of a product malfunction of the reported mapping catheter 990063-015, lot number 216142845 in relation to the adverse event.Pending analysis of the returned product.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Incoming information received that the mapping catheter was responsible for the perforation of the pulmonary vein.Additionally, the patient did not have to go to the operating room for surgical repair and has since been discharged from the hospital.
 
Additional Manufacturer Narrative
Product event summary: the mapping catheter, 990063-015 with lot number 216142845, was returned and analyzed.Visual inspection of the mapping catheter showed the device was intact with no apparent issue.Mechanical verification of the steering functioned normal.The reported clinical issues could not be confirmed through product analysis.The mapping catheter passed the returned product inspection as per specification.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ACHIEVE MAPPING CATHETER
Common Device Name
CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING
Manufacturer (Section D)
MEDTRONIC MEXICO
av. paseo del cucapah #10510
tijuana,bc 22570
MX  22570
MDR Report Key8203063
Report Number9612164-2018-03784
Device Sequence Number202349
Product Code DRF
UDI-Device Identifier00643169467378
UDI-Public00643169467378
Combination Product (Y/N)N
Initial Reporter StateOH
Initial Reporter CountryUS
PMA/510(K) Number
K102588
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 02/25/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date09/10/2020
Device Model Number990063-015
Device Catalogue Number990063-015
Device Lot Number216142845
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/05/2018
Initial Date Received by Manufacturer 12/04/2018
Supplement Date Received by Manufacturer01/02/2019
01/29/2019
Initial Report FDA Received Date12/28/2018
Supplement Report FDA Received Date01/25/2019
02/25/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Life Threatening; Required Intervention;
Patient Age70 YR
Patient Weight80
-
-