BD (SUZHOU) BD INTIMA-II¿ CLOSED IV CATHETER SYSTEM; INTRAVASCULAR CATHETER Back to Search Results
Catalog Number 383078
Device Problem Leak/Splash (1354)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 12/12/2018
Event Type  malfunction  
Manufacturer Narrative
A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event Description
It was reported that during use of the bd intima-ii¿ closed iv catheter system leaked.
 
Manufacturer Narrative
Investigation summary: a sample was received for the purpose of our investigation.A device history report was conducted for lot number 8107025, and no related abnormalities were found.This lot of intima ii was manufactured in july of 2018; bd engineers have noted a trend in leakage for this lot.According to the sampling plan applied for product performance, this lot was accepted and released, with no defects being noted during final assembly or visual inspections.Investigation conclusion: the investigators were able to observe the reported failure mode in the sample provided.A small cracked was found during leakage testing and was located on the adapter.The returned product's parameters for swage dimension and swage length were tested and found to be within product specifications.Root cause description: depending on pressure variance in the auto line's swage pressure, it is possible for the machine to become misaligned allowing for the resulting crack to form in the device.Bd is currently conducting a long term study to determine the root cause for this event.Rationale: bd will continue to track and trend for this issue.Capa # 642738 has been initiated to address this issue.
 
Event Description
It was reported that during use of the bd intima-ii¿ closed iv catheter system leaked.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD INTIMA-II¿ CLOSED IV CATHETER SYSTEM
Type of Device
INTRAVASCULAR CATHETER
Manufacturer (Section D)
BD (SUZHOU)
no. 5 baiyu road
suzhou industrial park
suzhou
MDR Report Key8206719
MDR Text Key131913150
Report Number3006948883-2018-00328
Device Sequence Number1
Product Code FOZ
UDI-Device Identifier00382903830787
UDI-Public382903830787
Combination Product (y/n)N
PMA/PMN Number
N/A
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,other,user facility
Type of Report Initial,Followup
Report Date 01/15/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/31/2018
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date06/06/2021
Device Catalogue Number383078
Device Lot Number8107025
Date Manufacturer Received12/12/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Other;
-
-