BOSTON SCIENTIFIC CORPORATION INNOVA VASCULAR; STENT, SUPERFICIAL FEMORAL ARTERY Back to Search Results
Model Number 26926
Medical Device Problem Codes Entrapment of Device (1212); Material Integrity Problem (2978)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 12/12/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Age at time of event: older than 18 years.
 
Event or Problem Description
It was reported that the stent became stuck on the guidewire.An innova stent was selected for use for a lower limb stent procedure in the left superficial femoral artery (sfa).The target lesion was moderately tortuous, severely calcified and 100% stenosed.During procedure, the stent delivery system became stuck to a non-bsc guidewire and the delivery shaft became stretched.The stent was then removed with the guidewire together, and the procedure was completed with another innova stent.There were no patient complications reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INNOVA VASCULAR
Common Device Name
STENT, SUPERFICIAL FEMORAL ARTERY
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key8214561
Report Number2134265-2018-64608
Device Sequence Number16841993
Product Code NIP
UDI-Device Identifier08714729873686
UDI-Public08714729873686
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
P140028
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 01/03/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date12/31/2018
Device Model Number26926
Device Catalogue Number26926
Device Lot Number0018733069
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/17/2018
Initial Report FDA Received Date01/03/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-