• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: INSTRUMENTATION LABORATORY ACL TOP 500 CTS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

INSTRUMENTATION LABORATORY ACL TOP 500 CTS Back to Search Results
Model Number 2800-40
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Therapeutic Response, Increased (2272)
Date of Event 12/17/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
An investigation was conducted that included a review of the instrument clot curves.All aptt results illustrated well-formed curve formation, with appropriate clotting times detected and no concerning errors or warnings.The conclusion is that the values obtained on the acl top 500 cts were appropriately determined by the analyzer and the instrument was performing as intended.Based on the above, there was no indication of an instrument malfunction and no remedial action is needed.
 
Event or Problem Description
A customer reported that their acl top 500 cts generated erroneous aptt results using hemosil synthasil.Four patients were administered an increased dose of heparin based on the erroneous aptt results.After the additional dose of heparin, the patients were monitored with no further reports of clinical implications.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ACL TOP 500 CTS
Common Device Name
ACL TOP
Manufacturer (Section D)
INSTRUMENTATION LABORATORY
180 hartwell road
bedford MA 01730
MDR Report Key8225762
Report Number1217183-2019-00001
Device Sequence Number2111981
Product Code GKP
UDI-Device Identifier08426950453499
UDI-Public08426950453499
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
PMA/510(K) Number
K160276
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 01/08/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device No Information
Device Model Number2800-40
Device Catalogue Number00000280040
Was Device Available for Evaluation? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 12/17/2019
Initial Report FDA Received Date01/08/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-