| Model Number |
US3513058 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Occlusion (1984); Vascular Dissection (3160)
|
| Date of Event |
12/11/2018
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
As the lot number for the device was provided, a manufacturing review will be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.(expiry date: 07/2020), (manufacturing date: 08/2018).The information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported through the results of a clinical trial that following an angioplasty procedure in the proximal 1/3 of the right superficial femoral artery with a focused force percutaneous transluminal angioplasty (pta) balloon dilatation catheter, non-flow limiting dissection was identified which required use of additional pta balloon, drug coated pta balloon, and placement of stent.The current status of the patient is unknown.
|
| |
|
Event or Problem Description
|
|
It was reported through the results of a clinical trial that following an angioplasty procedure in the proximal 1/3 of the right superficial femoral artery with a focused force percutaneous transluminal angioplasty (pta) balloon dilatation catheter, non-flow limiting dissection was identified which required use of additional pta balloon, drug coated pta balloon, and placement of stent.The current status of the patient is unknown.New information: it was reported through the results of a clinical study trial, approximately 12-month post index procedure, occlusion was identified via duplex ultrasound.No treatment has been provided at this moment.
|
| |
|
Additional Manufacturer Narrative
|
|
As the lot number for the device was provided, a manufacturing review will be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.
|
| |
|
Search Alerts/Recalls
|