| Catalog Number |
0117160 |
| Medical Device Problem Codes |
Device Appears to Trigger Rejection (1524); Defective Device (2588); Insufficient Device Problem Information (3190); Patient Device Interaction Problem (4001)
|
| Health Effect - Clinical Codes |
Adhesion(s) (1695); Pain (1994); Scar Tissue (2060); Hernia (2240); Injury (2348); Disability (2371)
|
| Date of Event |
07/22/2016
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
At this time no conclusions can be made regarding the bard/davol perfix light plug (device #1) used to treat the patient.No lot number has been provided therefore a review of the manufacturing records is not possible.Should additional information be provided a supplemental emdr will be submitted.This emdr represents the bard/davol perfix light plug (device #1).An additional emdr was submitted to represent the bard/davol perfix light plug (device #2) and bard/davol 3dmax (device #3).Not returned.
|
| |
|
Event or Problem Description
|
|
The following was alleged by the patient's attorney: (b)(6) 2013: the patient underwent surgery for implant of two (2) unspecified bard/davol perfix plug lite (device #1) and (device #2).On (b)(6) 2015: the patient underwent surgery for implant of an unspecified bard/davol 3dmax (device #3).The patient is making a claim for an adverse patient outcome against the two (2) perfix plug lite (device #1) and (device #2) and 3dmax (device #3).The patient;s attorney alleges general allegations for "past, present, and future damages, including but not limited to, mental and physical pain and suffering for severe and permanent personal injuries sustained by the patient.".
|
| |
|
Event or Problem Description
|
|
The following was alleged by the patient's attorney: (b)(6)2013: the patient underwent surgery for implant of two (2) unspecified bard/davol perfix plug lite (device #1) and (device #2).(b)(6)2015: the patient underwent surgery for implant of an unspecified bard/davol 3dmax (device #3).The patient is making a claim for an adverse patient outcome against the two (2) perfix plug lite (device #1) and (device #2) and 3dmax (device #3).The patient' s attorney alleges general allegations for "past, present, and future damages, including but not limited to, mental and physical pain and suffering for severe and permanent personal injuries sustained by the patient." addendum per additional information provided: (b)(6)2013- patient was diagnosed with bilateral inguinal hernia thereby underwent open repair with the implant of two perfix light plugs (device #1 and #2).Per operative notes, ¿on the left side, hernia sac was reduced into the internal ring.A large perfix light plug (device #1) was placed into the left internal inguinal ring and a patch was used to the floor of the inguinal canal using sutures.Attention to the right side, noted that there was a direct space hernia.A medium perfix light plug and patch (device #2) were tacked in the floor of the inguinal canal using sutures.¿ (b)(6)2015 - patient was diagnosed with recurrent bilateral inguinal hernias thereby underwent laparoscopic repair with the implant of two 3dmax meshes (device #3 and #4) and partial removal of plug (device #1).Per operative notes, ¿patient had recurrent bilateral inguinal hernias, both appeared to be indirect.In the right side, the indirect sac was quite adhesed to the previously placed mesh (device #2).The hernia sac was dissected away from the mesh.A large 3dmax (device #3) right sided patch was placed and secured to cooper¿s ligament.On the left side, hernia sac was adherent to the mesh plug (device #1) and this portion of the mesh plug had to be removed.The sac was completely reduced, a left sided 3dmax (device #4) was placed and secured to cooper¿s ligament.¿ (b)(6)2015 - patient was diagnosed with recurrent bilateral inguinal hernias thereby underwent laparoscopic repair with implant of two bard flat meshes (device #5 and #6) and removal of mesh (device #1).Per operative notes, ¿noted recurrent inguinal hernias (direct).Hernia reduced, placed a right-sided bard mesh (bard flat mesh - device #5) and secured with protack device.Left hernia tapp performed with protection of epigastric and iliac vessels, previously placed mesh plug (device #1) entering hernia defect, part of this plug excised (device #1), but some of it remained given the dense surrounding adhesions, hernia sac was reduced, placed a left sided bard mesh (bard flat mesh ¿ device #6).¿ (b)(6)2016 - patient was diagnosed with recurrent right inguinal hernia thereby underwent open repair with explantation of perfix light plug (device #2) and 3dmax mesh (device #3).Per operative notes, ¿patient had significant scar tissue and adhesions.The underlying mesh was densely adherent.Previously placed plug (device #2 and #3) which was protruding through the inguinal floor.This plug (device #2) was then explanted.¿ (b)(6)2016 - patient was diagnosed with recurrent right inguinal hernia thereby underwent open repair with removal of mesh (device #3).Per operative notes, ¿identified a piece of mesh seen adjacent to indirect space.Mesh piece (device #3) excised off surrounding structures.¿ attorney alleges that the patient had adhesions, hernia recurrence and pain.It is also alleged that the mesh had found protruding through the inguinal floor at the area of recurrence.
|
| |
|
Additional Manufacturer Narrative
|
|
At this time no conclusions can be made regarding the bard/davol perfix light plug (device #1) used to treat the patient.No lot number has been provided therefore a review of the manufacturing records is not possible.Addendum: this supplemental emdr is submitted to document additional information provided.Based on the additional information received, there is no change to initial determination, no conclusions can be made.Per medical records review, about 3 years post implant of perfix light plug patient was diagnosed with hernia recurrence, adhesions, scar tissue and mesh protrusion thereby underwent repair with removal of mesh.The instructions-for-use supplied with the device lists hernia recurrence and adhesions as possible complications.A review of the manufacturing records shows product was manufactured to specification.Note, the manufacturing date (15-feb-2013) is considered to be a best estimate.Update fields: a2, a4, b2, b3 (date of event), b4, b5, b6, b7, d4 (product catalog no, corporate lot no, expiry date, udi no), d.6b (date of explant), g1, g3, g6, h2, h4, h6, h10.This supplemental emdr represents perfix light plug (device #2).Additional supplemental emdr's were submitted to represent the 3dmax mesh (device #3) and perfix plug light (device #1).Additional emdr's were submitted to represent 3dmax mesh (device #4) and bard flat mesh (device #5).Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|