COVIDIEN LP LLC NORTH HAVEN V-LOC 180; SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID Back to Search Results
Model Number VLOCL1544
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 11/22/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
According to the reporter, during at the end of laparoscopic procedure bilateral inguinal hernia treatment, at the time of the suture of the peritoneum, on the right side, the thermo-welded stop loop at the end of the wire broke and the suture completely broke.The wire had been removed and the closure of the peritoneum was treated by hemlock clips and another v-loc wire from another batch.It results in a fragilization of the peritoneum with occlusion risks from the potential contact between the prothesis and the small intestine.
 
Event or Problem Description
According to the reporter, during at the end of laparoscopic procedure bilateral inguinal hernia treatment, at the time of the suture of the peritoneum, on the right side, the thermo-welded stop loop at the end of the wire broke and the suture completely broke.The wire had been removed and the closure of the peritoneum was treated by hemlock clips and another v-loc wire from another batch.It results in a fragilization of the peritoneum with occlusion risks by the potential contact between the prothesis and the small intestine.There was no patient injury.
 
Additional Manufacturer Narrative
Evaluation summary: post market vigilance (pmv) led an evaluation of eleven devices.The visual inspection of the opened sample noted one suture and one needle attached.The suture was returned with the loop opened.Under microscopic inspection, material transfer was observed at the weld site.Visual inspection and functional testing of the sealed products confirmed there were no abnormalities that would have caused or contributed to the reported condition.A review of the device history record indicates this product was released meeting all quality release specifications at the time of manufacture.The investigation concluded there were no abnormalities that would have caused or contributed to the reported condition.A definitive root cause could not be determined with regard to the reported condition.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
V-LOC 180
Common Device Name
SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC ACID
Manufacturer (Section D)
COVIDIEN LP LLC NORTH HAVEN
195 mcdermott rd
north haven CT 06473
MDR Report Key8265445
Report Number1219930-2019-00443
Device Sequence Number16733669
Product Code GAM
UDI-Device Identifier10884521131460
UDI-Public10884521131460
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K091087
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2018
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 05/13/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/30/2021
Device Model NumberVLOCL1544
Device Catalogue NumberVLOCL1544
Device Lot NumberA8D0997VX
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/26/2019
Initial Date Received by Manufacturer 12/26/2018
Supplement Date Received by Manufacturer04/23/2019
Initial Report FDA Received Date01/21/2019
Supplement Report FDA Received Date05/13/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-