Model Number 6533
Medical Device Problem Code Physical Resistance/Sticking (4012)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 12/10/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device evaluated by mfr.: returned product consisted of a nc quantum apex balloon catheter.The outer shaft, inner shaft, balloon and tip were visually and microscopically examined.Visual examination revealed multiple minor kinks along the hypotube.Microscopic examination revealed that the guidewire lumen is buckled 47mm from the tip and is approximately 2mm long.There is a hole in the guidewire lumen in the buckled section approximately 48mm from the tip.The balloon is still tightly folded.The guide wire used in the clinical procedure was not returned with the device so a test guide wire was used for functional testing.A.014 in test guide wire was advanced into the guide wire lumen and was unable to pass the buckled section.Inspection of the remainder of the device presented no other damage or irregularities.
 
Event or Problem Description
Reportable based on device analysis completed on 04-jan-2019.It was reported that loading difficulties were encountered.The target lesion was located in a coronary artery.A 20mm x 3.50mm nc quantum apex and a 2.50mm x 12mm emerge balloon catheters were selected for use; however, both devices could not be loaded over the wire.The procedure was completed with a non-bsc device.No patient complications were reported since the devices did not enter the patient's body.However, returned device analysis revealed hole in shaft material.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NC QUANTUM APEX
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key8273668
Report Number2134265-2019-00276
Device Sequence Number1448801
Product Code LOX
UDI-Device Identifier08714729783503
UDI-Public08714729783503
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K121667
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 01/24/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/13/2021
Device Model Number6533
Device Catalogue Number6533
Device Lot Number0022934855
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/20/2018
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/04/2019
Initial Report FDA Received Date01/24/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-