• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON DICKINSON, S.A. BD¿ PHASEAL; INTRAVASCULAR ADMINISTRATION SET

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON DICKINSON, S.A. BD¿ PHASEAL; INTRAVASCULAR ADMINISTRATION SET Back to Search Results
Catalog Number 515004
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 01/08/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Medical device expiration date: unknown.(b)(6).Device manufacture date: unknown a device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported that six bd phaseals had leakage when preparing for compounding.
 
Additional Manufacturer Narrative
H.6.Investigation summary: two picture samples were received for evaluation by our quality engineer team.Upon visual inspection of the pictures, it was observed that the bag containing the syringe, injector, protector, and vial was stained with the drug.Through the picture samples, it was not possible to confirm the point of leakage.As a lot number was unknown for this incident, a device history record review could not be completed and additional retained samples could not be investigated.Based on the limited investigation results, a cause for the reported incident could not be determined.Leakage-others in pictures received, the bag containing the syringe/injector/protector/vial is stained with drug.It is no possible to confirm the point of leak.Apparently, injector and protector seem to be properly attached between them and to the vial.Inspections and tests in manufacturing area for protectors: protector housing were manufactured by nolato supplier.Currently, they are molded in bd san agustin plant.Visual inspections and critical dimensions for protector housing parts are performed according to ph-300 current version.During assembly process, the operator performs the following inspections and tests according to ph-302 current version: it is verified that expansion film of the bladder is centered in the protector housing, correctly sealed and free of holes or damages.-visual inspection of the filter is performed to verify that is centered in the protector cavity, welded in a right position and free of holes between the filter and filter cover.-overpressure test is performed to verify that the expansion film of the bladder can resist certain pressure.Film breakage test: the expansion film of the bladder must break at minimum pressure (0,8 bar).It is verify if the break is produced in the sealing area or at the film.Functionality test is performed to ensure properly work of the protector.Hydrophobic filter leakage is performed to verify that no leaks are present in the filter.
 
Event or Problem Description
It was reported that six bd¿ phaseals had leakage when preparing for compounding.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD¿ PHASEAL
Common Device Name
INTRAVASCULAR ADMINISTRATION SET
Manufacturer (Section D)
BECTON DICKINSON, S.A.
camino de valdeolivia
s/n
san agustin de guadalix
MDR Report Key8282818
Report Number3003152976-2019-00114
Device Sequence Number13951037
Product Code ONB
UDI-Device Identifier30382905150044
UDI-Public30382905150044
Combination Product (Y/N)N
Initial Reporter CountrySW
PMA/510(K) Number
K140591
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign,other,user facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 02/11/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Other
Device Catalogue Number515004
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 01/11/2019
Supplement Date Received by Manufacturer01/11/2019
Initial Report FDA Received Date01/28/2019
Supplement Report FDA Received Date02/11/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-