• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: STRYKER TRAUMA KIEL LOCKING SCREW, FULLY THREADED T2 TIBIA Ø5X40 MM; ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER TRAUMA KIEL LOCKING SCREW, FULLY THREADED T2 TIBIA Ø5X40 MM; ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES Back to Search Results
Catalog Number 18965040S
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 01/16/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device will not be returned.If additional information becomes available it will be provided on a supplemental report.Device evaluated by mfr: device remains implanted.
 
Event or Problem Description
The surgeon reported that he was undertaking a 2 stage revision of knee and decided to use a gamma nail as a spacer.During the case he inserted the nail and when he inserted one of the screws it was the wrong size.The screw was not fully seated and when the surgeon tried to remove it, it cold welded itself onto the nail.The surgeon left e nail and screw in situ.The reported event resulted in a 2 hour delay to surgery and the surgeon was concerned about the risk of infection due to the length of time the patient was on the table.
 
Additional Manufacturer Narrative
This device is concomitant and did not contribute to the reported failure.If any additional information is provided indicating otherwise the investigation will be updated accordingly and a supplemental report will be provided.
 
Event or Problem Description
The surgeon reported that he was undertaking a 2 stage revision of knee and decided to use a gamma nail as a spacer.During the case he inserted the nail and when he inserted one of the screws it was the wrong size.The screw was not fully seated and when the surgeon tried to remove it, it cold welded itself onto the nail.The surgeon left e nail and screw in situ.The reported event resulted in a 2 hour delay to surgery and the surgeon was concerned about the risk of infection due to the length of time the patient was on the table.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LOCKING SCREW, FULLY THREADED T2 TIBIA Ø5X40 MM
Common Device Name
ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES
Manufacturer (Section D)
STRYKER TRAUMA KIEL
prof. kuentscher-strasse 1-5
schoenkirchen/kiel D-242 32
MDR Report Key8337608
Report Number0009610622-2019-00067
Device Sequence Number10808792
Product Code HSB
UDI-Device Identifier04546540202499
UDI-Public04546540202499
Combination Product (Y/N)N
Initial Reporter CountryGB
PMA/510(K) Number
K032244
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/22/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Catalogue Number18965040S
Device Lot NumberK08F2C2
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 01/16/2019
Supplement Date Received by Manufacturer04/02/2019
Initial Report FDA Received Date02/13/2019
Supplement Report FDA Received Date04/22/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-