• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BD MEDICAL (BD WEST) MEDICAL SURGICAL NEEDLE 19GA 1IN TW; CONVENTIONAL NEEDLES

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BD MEDICAL (BD WEST) MEDICAL SURGICAL NEEDLE 19GA 1IN TW; CONVENTIONAL NEEDLES Back to Search Results
Catalog Number 305186
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 01/29/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported that three needle 19ga 1in tw experienced foreign matter contamination noted prior to use.
 
Additional Manufacturer Narrative
One sample and one photo were provided for evaluation.The sample has a white epoxy drip over on the plastic shield.The epoxy got also stuck to the plastic shield.The photo shows the same defect as the sample.Failure mode is verified.An epoxy drip over generally occurs when the epoxy applicator fails to shut off for a missing cannula.There are several contributing / possible factors.A dirty sensor that doesn't shut the epoxy off for a missing cannula the epoxy pressure is too high.The epoxy applicator needs attention ¿ it isn¿t shutting off when it should.The epoxy viscosity is also related to temperature fluctuations.If the temperature goes up, the epoxy gets thinner and flows faster.A device history record review was completed with zero defects found.No quality notifications were written for this batch, nor for the associated assembly batches.
 
Event or Problem Description
It was reported that three needle 19ga 1in tw experienced foreign matter contamination noted prior to use.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NEEDLE 19GA 1IN TW
Common Device Name
CONVENTIONAL NEEDLES
Manufacturer (Section D)
BD MEDICAL (BD WEST) MEDICAL SURGICAL
1852 10th avenue
columbus NE 68601
MDR Report Key8354043
Report Number1911916-2019-00198
Device Sequence Number19311641
Product Code FMI
UDI-Device Identifier00382903051861
UDI-Public00382903051861
Combination Product (Y/N)N
Initial Reporter StateND
Initial Reporter CountryUS
PMA/510(K) Number
K021475
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source other,user facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/06/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date02/28/2023
Device Catalogue Number305186
Device Lot Number7361735
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 01/30/2019
Supplement Date Received by Manufacturer01/30/2019
Initial Report FDA Received Date02/20/2019
Supplement Report FDA Received Date03/06/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-