MAUDE Adverse Event Report: STRYKER GMBH PLATE ANCHORAGE MTP / VERSION V2 - RIGHT; PLATE, FIXATION, BONE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER GMBH PLATE ANCHORAGE MTP / VERSION V2 - RIGHT; PLATE, FIXATION, BONE Back to Search Results
Catalog Number PLP11342
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 01/22/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Once the investigation has been completed any additional information will be reported in a supplemental report.
 
Event or Problem Description
The following event was reported by clinic: despite the use of the barrel on the plate anchorage mtp right (ref plp11342), the screw diameter 3 locking does not fit correctly in the hole.Threading problem was observed and 1 wire came out of the screw.The screw protrudes from the plate and a metal wire comes out of the screw.The screw was removed and another screw reinserted.
 
Event or Problem Description
The following event was reported by clinic: " despite the use of the barrel on the plate anchorage mtp right (ref plp11342), the screw diameter 3 locking does not fit correctly in the hole.Threading problem was observed and 1 wire came out of the screw.The screw protrudes from the plate and a metal wire comes out of the screw.The screw was removed and another screw reinserted.
 
Additional Manufacturer Narrative
This device is concomitant and did not contribute to the reported failure.Therefore, this complaint is closed without further investigation.If any additional information is provided indicating otherwise the record will be reopened and the investigation will be reworked.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PLATE ANCHORAGE MTP / VERSION V2 - RIGHT
Common Device Name
PLATE, FIXATION, BONE
Manufacturer (Section D)
STRYKER GMBH
bohnackerweg 1
postfach
selzach 2545
CH  2545
MDR Report Key8356235
Report Number0008031020-2019-00070
Device Sequence Number1599679
Product Code HRS
UDI-Device Identifier07613252260516
UDI-Public07613252260516
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K083447
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Pharmacist
Type of Report Initial,Followup
Report Date (Section B) 04/05/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberPLP11342
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Yes
Initial Date Received by Manufacturer 01/23/2019
Supplement Date Received by Manufacturer03/21/2019
Initial Report FDA Received Date02/20/2019
Supplement Report FDA Received Date04/05/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-