• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON DICKINSON MEDICAL SYSTEMS SYR SAFETYLOK 10ML LL W/NDL 21X1-1/2 TW; HYPODERMIC SINGLE LUMEN NEEDLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON DICKINSON MEDICAL SYSTEMS SYR SAFETYLOK 10ML LL W/NDL 21X1-1/2 TW; HYPODERMIC SINGLE LUMEN NEEDLE Back to Search Results
Catalog Number 305564
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 12/28/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported that the syr safetylok 10ml ll w/ndl 21x1-1/2 tw experienced leakage around the plunger.
 
Additional Manufacturer Narrative
Investigation summary: no samples displaying the condition reported are available for examination.We were unable to fully investigate this incident, therefore a root cause could not be determined.Furthermore, a device history record review showed no rejected inspections or quality issues during the production of the provided lot number that could have contributed to the reported defect.
 
Event or Problem Description
It was reported that the syr safetylok 10ml ll w/ndl 21x1-1/2 tw experienced leakage around the plunger.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYR SAFETYLOK 10ML LL W/NDL 21X1-1/2 TW
Common Device Name
HYPODERMIC SINGLE LUMEN NEEDLE
Manufacturer (Section D)
BECTON DICKINSON MEDICAL SYSTEMS
route 7 and grace way
canaan CT 06018
MDR Report Key8358989
Report Number1213809-2019-00253
Device Sequence Number16623177
Product Code FMI
UDI-Device Identifier30382903055648
UDI-Public30382903055648
Combination Product (Y/N)N
Initial Reporter StateVA
Initial Reporter CountryUS
PMA/510(K) Number
K944757
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source other,user facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 04/16/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date05/31/2023
Device Catalogue Number305564
Device Lot Number8166897
Initial Date Received by Manufacturer 02/01/2019
Supplement Date Received by Manufacturer02/01/2019
Initial Report FDA Received Date02/21/2019
Supplement Report FDA Received Date04/16/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-