SMITH & NEPHEW, INC. JRNY II BCS XLPE ART ISRT SZ 1-2 RT 12MM; PROSTH, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONST, CEMENTED, POLY/METAL/POLY Back to Search Results
Catalog Number 74027214
Medical Device Problem Code Insufficient Device Problem Information (3190)
Health Effect - Clinical Code Unspecified Infection (1930)
Date of Event 02/05/2019
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a revision surgery was performed due to infection on the right side.Insert was exchanged.
 
Additional Manufacturer Narrative
A clinical evaluation was conducted and it has been communicated that no clinical documents are available.Therefore, no thorough clinical assessment of the reported issue can be rendered.Should additional information be provided, the clinical/medical investigation task will be reopened.A review of complaint history on the listed part revealed no prior complaints for the listed batch with the same failure mode.A review of the manufacturing records did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.Without the actual product involved and/or device information, our investigation cannot proceed.If the device or new information is received in the future, this complaint can be re opened.Mimb review: assess severity of complaint case to determine if additional action and further inputs are required for inclusion in medical assessment.Determine if a medical assessment would be performed based on a review of the complaint detail and further recommendations from the medical director/designee.Reviewed during mimb.A medical investigation will be performed.Proceed based on information provided/available for the investigation; if no relevant clinical information is provided, recommend closure.Approved by (b)(6), medical director.A review of relevant clinical/medical information in the reported issue, inclusive of technique and patient information, to include, but not limited to: patient information.Surgical procedure/post-operative care review.Device labeling (including technique guides, ifus, etc.) it has been communicated that no clinical documents are available.Therefore, no thorough clinical assessment of the reported issue can be rendered.Should additional information be provided, the clinical/medical investigation task will be reopened.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
JRNY II BCS XLPE ART ISRT SZ 1-2 RT 12MM
Common Device Name
PROSTH, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONST, CEMENTED, POLY/METAL/POLY
Manufacturer (Section D)
SMITH & NEPHEW, INC.
1450 brooks road
memphis TN 38116
MDR Report Key8380870
Report Number1020279-2019-00882
Device Sequence Number16206456
Product Code JWH
UDI-Device Identifier00885556178812
UDI-Public00885556178812
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K122170
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2019
Reporter Type Manufacturer
Report Source foreign,health professional,u
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 06/15/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date02/21/2026
Device Catalogue Number74027214
Device Lot Number16BM17327
Initial Date Received by Manufacturer 02/07/2019
Supplement Date Received by Manufacturer06/10/2019
Initial Report FDA Received Date03/01/2019
Supplement Report FDA Received Date06/15/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-