| Catalog Number |
6260-9-328 |
| Medical Device Problem Codes |
Degraded (1153); Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Codes |
Inflammation (1932); Injury (2348); Reaction (2414); Metal Related Pathology (4530)
|
| Date of Event |
11/26/2018
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The information in this report was provided by stryker orthopaedics legal affairs department.No additional information is available at this time due to the ongoing litigation.Should additional information become available, the evaluation summary will be submitted in a supplemental report.Device not available.
|
| |
|
Event or Problem Description
|
|
It was reported that allegedly the patient was implanted with an lfit anatomic cocr v40 femoral head on her left hip on or about (b)(6) 2008 and was revised on (b)(6) 2018.It is further alleged that she suffered injuries as a result of implantation and explantation of the device at issue, and excessive levels of chromium and cobalt in her blood.
|
| |
|
Additional Manufacturer Narrative
|
|
An event regarding abnormal ion levels and metallosis involving a metal head was reported.The event was not confirmed.Method & results: device evaluation and results: not performed as product was not returned.Clinician review: a review of the provided medical records by a clinical consultant indicated: relevant clinical history and timelines: this product inquiry concerns a patient who underwent a left total hip arthroplasty with an accolade tmzf stem and an lfit femoral head on or about (b)(6) 2008.The patient required revision of the hip arthroplasty on (b)(6) 2018.Metallosis was found around the head and neck area with black metal debris around the area.The surgeon removed the stem and the revision was carried out.Conclusion of assessment: this case concerns a patient who underwent a cementless left total hip arthroplasty and then approximately 10 years later required revision for metallosis.No mention was made in the information i reviewed that corroborates elevated metal ion levels.The root cause of this event cannot be determined with certainty.Causes of metallosis are multifactorial including surgical technique factors, especially in the preparation and implantation of the femoral head, patient factors such as activity level and bmi, and implant factors.The explanted prosthesis should be submitted to stryker engineers for metallurgical evaluation and examination to determine if any to determine if any defects or abnormalities were present.Whether or not, there was a product recall, must be determined by stryker.Device history review: all devices were manufactured and accepted into final stock with no relevant reported discrepancies.Complaint history review: there have been no other similar events for the reported lot.Conclusion: the exact cause of the event could not be determined because insufficient information was provided.A review of the provided medical records by a clinical consultant indicated: ' this case concerns a patient who underwent a cementless left total hip arthroplasty and then approximately 10 years later required revision for metallosis.No mention was made in the information i reviewed that corroborates elevated metal ion levels.The root cause of this event cannot be determined with certainty.Causes of metallosis are multifactorial including surgical technique factors, especially in the preparation and implantation of the femoral head, patient factors such as activity level and bmi, and implant factors.The explanted prosthesis should be submitted to stryker engineers for metallurgical evaluation and examination to determine if any to determine if any defects or abnormalities were present.Whether or not, there was a product recall, must be determined by stryker.' if further information becomes available or the product is returned, this investigation will be re-opened.
|
| |
|
Event or Problem Description
|
|
It was reported that allegedly the patient was implanted with an lfit anatomic cocr v40 femoral head on her left hip on or about (b)(6) 2008 and was revised on (b)(6) 2018.It is further alleged that she suffered injuries as a result of implantation and explantation of the device at issue, and excessive levels of chromium and cobalt in her blood.Update per medical records received from legal 03-oct-2023: "pre-op diagnosis: painful left total hip arthroplasty with a recalled implant.Post-op diagnosis: ____ of the left total hip arthroplasty with wear in the metal head and neck area.Metalosis around the head and neck area with black metal debris around the area.At this point, the stem was removed using a combination of osteotomes and disimpactors, which was removed uneventfully with minimal clear splitting with the osteotome.".
|
| |
|