Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report. corrected: (method, conclusion, and result).Product complaint # (b)(4).Investigation summary : the complaint sample consisted of (1) 950502071 hp power pin driver, (1) 950502089 hp threaded pin headed, (1) 201103023 sig hp rev distal spacer 12mm and (1) 201103003 sig hp rev 4in1 cut blk sz4 the sample was submitted with the hp threaded pin headed jammed in the pin hole of the sig hp rev 4in1 cut blk sz4.The pin head has broken off and is lodged inside the hp power pin driver and cannot be removed.In addition, the pin is significantly bent and deformed.The sig hp rev distal spacer 12mm was returned stuck on the bent hp threaded pin headed.The spacer cannot be removed due to the bent condition of the pin.The stuck spacer is secondary to the pin damage.Although the investigation could not conclusively identify the root cause of the pin breakage/damage, it is likely off-axis loading of the pin into the block pin hole was a contributing factor.The hp power pin driver continued to rotate on the head of the pin after the pin became jammed in the block resulting in torsional fracture and bending of the pin.The root cause is being attributed to unintended user technique of off-axis loading of the pin into the block pin hole.The damage to the pin driver and spacer were secondary to the pin breakage/damage.Based on the investigation determination of unintended user error as the primary root cause, the need for corrective action is not indicated.Complaint trends will be monitored by post market surveillance through sep-419.Depuy considers the investigation closed at this time.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate. .
|
|
Product complaint #: (b)(4).Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|