| Catalog Number |
5520B500 |
| Medical Device Problem Code |
Osseointegration Problem (3003)
|
| Health Effect - Clinical Codes |
Arthritis (1723); Injury (2348); Inadequate Osseointegration (2646)
|
| Date of Event |
01/08/2014
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The information in this report was provided by stryker orthopaedics legal affairs department.It was noted that the device is not available for evaluation.Review of the device history records indicate that devices were manufactured and accepted into final stock with no reported discrepancies.There have been no other events for the lot referenced.If additional information is received, it will be provided in a supplemental report upon completion of the investigation.Device not available.
|
| |
|
Event or Problem Description
|
|
It was reported that allegedly the patient was revised due to "right knee osteoarthritis and right knee total arthroplasty failure or loosening.".
|
| |
|
Additional Manufacturer Narrative
|
|
Reported event: an event regarding loosening involving a triathlon baseplate was reported.The event was confirmed through clinician review of the provided medical records.Method & results: -product evaluation and results: not performed as no product was returned for evaluation.-clinician review: a review of the provided medical records by a clinical consultant stated the following comment: a single ap of the primary tka dated (b)(6) 2012 was reviewed.The femoral component is in its expected position.Interfaces are not visible for the femoral component on ap view and i cannot comment on fixation.Tibial component was undersized in a few degrees of varus.There is a slight lucency beneath the medial plateau of the tibial component otherwise the tibial component appears well fixed.No x-rays demonstrating reported lucencies beneath the tibial plateau nor the bone scan were available for review.2 ap x-rays of a stemmed revision tka dated (b)(6) 2014 components are in satisfactory position and the stems and implants appear well fixed.Review of the records confirm revision surgery was carried out for aseptic loosening of a tibial component in a cemented tka.Records do not provide any evidence for a root cause of the aseptic loosening.Product history review: indicated all devices were manufactured and accepted into final stock with no reported discrepancies.Complaint history review: there have been no other similar events for the lot referenced.Conclusions: the exact cause of the event could not be determined because insufficient information was provided.Further information such as device return, pre and post operative x-rays, operative reports as well as patient history and follow up notes are required to complete the investigation for determining a root cause.
|
| |
|
Event or Problem Description
|
|
It was reported that allegedly the patient was revised due to "right knee osteoarthritis and right knee total arthroplasty failure or loosening." update:review of the records confirm revision surgery was carried out for aseptic loosening of a tibial component in a cemented tka.
|
| |
|