Model Number 6532
Medical Device Problem Code Material Rupture (1546)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 02/26/2019
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that balloon rupture occurred.The target lesion as located in the severely tortuous and calcified left anterior descending artery.A 2.50x20mm synergy ii drug-eluting stent was advanced for treatment.However, the device was unable to be delivered.When it was removed from the patient's body, it was noticed that the proximal edge of the stent struts were damaged.Another stent of the same sized was advanced to the lesion.Subsequently, a 1.2mm x 12mm threader balloon catheter was advanced but it failed to cross the lesion.Another 15mm x 3.00mm nc quantum apex balloon catheter was advanced for dilatation.However, during inflation, the balloon ruptured.The physician grabbed another balloon and completed the procedure.No patient complications were reported and the patient's status was fine.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NC QUANTUM APEX
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key8429519
Report Number2134265-2019-02620
Device Sequence Number240564
Product Code LOX
UDI-Device Identifier08714729783374
UDI-Public08714729783374
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K121667
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 03/18/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/03/2022
Device Model Number6532
Device Catalogue Number6532
Device Lot Number0023138114
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/26/2019
Initial Report FDA Received Date03/18/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-