Model Number 71002-026
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 12/14/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
No evaluation possible at this time.The international customer has not returned the device for evaluation.Upon the receipt of additional information and/or the product in question, a follow-up report will be submitted.
 
Event or Problem Description
When placing the plate and inserting the screws for tightening, the secure central golden piece jumped.Fortunately, it was retrieved with no consequences to the patient.Finally, a new plate was used instead.No patient harm reported.
 
Additional Manufacturer Narrative
Visual examination of the returned 2-level plate found that the middle blocking slide had become completely detached from the implant.Witness marks along both the anterior and posterior sides of the plate are present and reveal the location of the instrument to plate during contouring/bending.The plate contains a witness mark on the posterior side directly behind the location of the detached blocking slide and witness marks at both graft windows on the anterior side.The combination of these witness marks confirms the plate bending instrument was positioned inconsistent with ifu requirements while contouring/bending the plate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ANTERIOR CERVICAL PLATE ASSEMBLY, 2-LEVEL, 026 MM (TI-6AI-4V ELI, NITINOL)
Common Device Name
SPINAL INTERVERTEBRAL BODY FIXATION ORTHOSIS
Manufacturer (Section D)
ALPHATEC SPINE INC
5818 el camino real
carlsbad CA 92008
MDR Report Key8451790
Report Number2027467-2019-00012
Device Sequence Number13788442
Product Code KWQ
UDI-Device Identifier00844856066977
UDI-Public(01)00844856066977(10)697688
Combination Product (Y/N)N
Initial Reporter CountrySP
PMA/510(K) Number
K102820
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 02/26/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number71002-026
Device Catalogue Number71002-026
Device Lot Number697688
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/12/2019
Initial Date Received by Manufacturer 02/26/2019
Supplement Date Received by Manufacturer02/26/2019
Initial Report FDA Received Date03/26/2019
Supplement Report FDA Received Date04/30/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-