MAUDE Adverse Event Report: COOK INC TUOHY-BORST LARGE BORE CLEAR PLASTIC SIDEARM ADAPTER; KGZ ACCESSORIES, CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK INC TUOHY-BORST LARGE BORE CLEAR PLASTIC SIDEARM ADAPTER; KGZ ACCESSORIES, CATHETER Back to Search Results
Catalog Number PTBYC-RA
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Occupation: other healthcare professional.Pma/510(k) number: pre-amendment.This report includes information known at this time.A follow-up report will be submitted should additional relevant information become available.
 
Event or Problem Description
It was reported, during an embolization procedure, the tuohy-borst large bore clear plastic sidearm adapter leaked when connected to another manufacturer's catheter.Reportedly, the complaint device would not tighten down on the microcatheter.The back-end leaked.This occurred during prepping and during the procedure.However, the procedure was successfully completed with the device.The patient did not experience any adverse effects as a result of this procedure.No additional interventions were required.This event occurred in three distinct procedures which are reported under medwatch report references: 1820334-2019-00746 and 1820334-2019-00748.Each of these three events occurred on either (b)(6) 2019.The complaint device for this event was discarded at the facility.Reportedly, four unused devices are available to aid in the manufacturer's investigation.
 
Additional Manufacturer Narrative
Blank fields on this form indicate the information is unknown, unavailable, or unchanged.A review of the functional test, inspection of unused product, complaint history, device history record, manufacturing instructions, drawing, quality control, specifications, and a visual inspection of the returned device were conducted during the investigation.The visual inspection of the four returned, unused devices did not reveal any damage.The seals of the devices were examined, and none of the devices leaked during testing.There is no evidence to suggest that the devices were not manufactured to specification.Additionally, a document-based investigation evaluation was performed.There is no evidence to suggest the product was not made to specifications.A review of the device history record showed no nonconforming events which could contribute to this failure mode.It should be noted there were two other reported complaints for this lot number, both reported at the same time and from the same customer as this complaint.Furthermore, a review of the manufacturer¿s instructions, drawing, and quality control procedures was conducted, and no gaps were discovered.Moreover, the product labeling provided with the device was also reviewed, but it does not address this specific failure mode.Based on the information provided, the examination of the returned product, and the results of our investigation, the cause of this event can be traced to the user and unintended use error.We will continue our monitoring of similar complaints and have notified the appropriate personnel of this event.Per the quality engineering risk assessment, no further action is required.
 
Event or Problem Description
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TUOHY-BORST LARGE BORE CLEAR PLASTIC SIDEARM ADAPTER
Common Device Name
KGZ ACCESSORIES, CATHETER
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key8478927
Report Number1820334-2019-00747
Device Sequence Number1920012
Product Code KGZ
UDI-Device Identifier00827002062993
UDI-Public(01)00827002062993(17)230919(10)9174778
Combination Product (Y/N)N
Initial Reporter StateAZ
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 04/25/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/19/2023
Device Catalogue NumberPTBYC-RA
Device Lot Number9174778
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/02/2019
Initial Date Received by Manufacturer 03/28/2019
Supplement Date Received by Manufacturer04/23/2019
Initial Report FDA Received Date04/03/2019
Supplement Report FDA Received Date04/25/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-