| Catalog Number |
0112950 |
| Medical Device Problem Codes |
Defective Device (2588); Insufficient Device Problem Information (3190); Patient Device Interaction Problem (4001)
|
| Health Effect - Clinical Codes |
Adhesion(s) (1695); Pain (1994); Hernia (2240); Injury (2348)
|
| Date of Event |
09/10/2018
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
At this time no conclusions can be made.The attorney alleges that the patient had subsequent surgical intervention; however no details have been provided.The cause of the patient postoperative complications cannot be determined at this time.No lot number has been provided therefore a review of the manufacturing records is not possible at this time.Information is limited.Should additional information be provided a supplemental emdr will be submitted.Not returned.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol perfix plug on (b)(6) 2015.It is alleged that the patient had subsequent surgical intervention due to the hernia mesh device(s).As reported, the patient is making a claim for an adverse patient outcome against the bard/davol perfix plug.As reported, the attorney alleges patient experienced emotional distress and the device was defective.
|
| |
|
Additional Manufacturer Narrative
|
|
At this time no conclusions can be made.The attorney alleges that the patient had subsequent surgical intervention;however no details have been provided.The cause of the patient postoperative complications cannot be determined at this time.No lot number has been provided therefore a review of the manufacturing records is not possible at this time.Information is limited.Addendum: this supplemental emdr is submitted to document additional information provided.Root cause is inconclusive, no conclusion can be made as to the extent to which the implant may have caused or contributed to the patient's postoperative course.Note, the manufacturing date (15-feb-2013) is considered to be a best estimate.Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol perfix plug on (b)(6) 2015.It is alleged that the patient had subsequent surgical intervention due to the hernia mesh device(s).As reported, the patient is making a claim for an adverse patient outcome against the bard/davol perfix plug.As reported, the attorney alleges patient experienced emotional distress and the device was defective.Addendum per additional information provided: (b)(6) 2015 - patient was diagnosed with left inguinal hernia thereby underwent repair with implant of perfix plug.(note: no implant op notes were provided for this procedure.) (b)(6) 2018 - patient was diagnosed with recurrent left inguinal hernia, pain thereby underwent laparoscopic repair with removal of perfix plug and implant of synthetic mesh.Per op notes, "the perfix plug adhered laterally was dissected free and completely removed.A synthetic mesh was placed and sutured.".
|
| |
|