| Model Number |
B2-70071-DF |
| Medical Device Problem Codes |
Fluid/Blood Leak (1250); Leak/Splash (1354); Mechanical Problem (1384)
|
| Health Effect - Clinical Code |
No Patient Involvement (2645)
|
| Date of Event |
04/23/2019
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
On (b)(6) 2019, the distributor confirmed with zyno medical that the administration set was discarded by the user facility and would not be returned for evaluation.The other affected device from the same lot which is reported under mdr #3006575795-2019-00009, would be evaluated by a service provider.
|
| |
|
Event or Problem Description
|
|
Zyno medical received a needless injection site leaking issue from a distributor representative on (b)(6) 2019.The distributor representative forwarded an email on (b)(6) 2019 from the user facility, which indicated that the user "had two tubing failures today of zyno tubing and that the drugs had to be wasted".It was also reported that "the leaks occured where the needleless injection port enters the iv tubing.She mentioned the set had a filter and was 105" long.She saved one of the tubing and medication sets, while the other was discarded due to having a lot of the patient's blood that leaked and backed up in the tubing".On (b)(6) 2019, the distributor reported more information obtained from the user facility: "after we had those 2 tubing failures we switched to tubing with different lot numbers.We now have approx.7 boxes with the lot # that leaked.I tried to replicate it again with another set and was unable to.I will send you the tubing with the simponi aria bag attached.Let me know if you need anything else.I don't know if this was random or a problem with this lot."the medication infused at the time of the event was simponi aria.No secondary set is used at the time of the event.This report is about the affected device that has been discarded at the user facility site.The other device that is returned is reported under mdr #3006575795-2019-00009.The contract manufacturer of the affected device is becton, dickinson and company.
|
| |
|
Event or Problem Description
|
|
This is a follow up report for the initially submitted mdr (3006575795-2019-00010).
|
| |
|
Additional Manufacturer Narrative
|
|
On 05/09/2019, the distributor of zyno medical forwarded this evaluation results to zyno medical.The reported leaking issue at the needless injection site was confirmed.Another affected device from the same lot (reported under mdr #3006575795-2019-00009) was evaluated by a service provider on 05/08/2019.During testing, leakage was found at the bottom of the needleless injection site.
|
| |
|