Model Number 0046160
Device Problems Failure to Capture (1081); Positioning Problem (3009)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Type  malfunction  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The device was not returned.
 
Event Description
It was reported that during the x-ray to confirm placement the ng tube could not be seen.The tube was placed in a patient with gastrointestinal bleeding and placement was confirmed by auscultation and from the return of gastric contents, but the x-ray did not demonstrate where the tube was placed.It was later reported per additional information from the complainant via email on (b)(6) 2019: the ng tube was continued to be used and was not replaced.There was not any reported impact to the patient.
 
Event Description
It was reported that during the x-ray to confirm placement the ng tube could not be seen.The tube was placed in a patient with gastrointestinal bleeding and placement was confirmed by auscultation and from the return of gastric contents, but the x-ray did not demonstrate where the tube was placed.It was later reported per additional information from the complainant via email on 19-apr-2019: the ng tube was continued to be used and was not replaced.There was not any reported impact to the patient.
 
Manufacturer Narrative
The device was not returned for evaluation.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: ¿1.Use with caution in patients with a history of head trauma, facial trauma, esophageal diseases and patients with potential for vomiting.2.Do not force nasogastric tube during insertions; damage to the nasal passage and mucosa and bleeding may occur.3.Measure insertion length carefully- excessive insertion length of tube into the stomach may lead to coiling and/or formation of tube-knot.4.Lubricate the tube generously with water soluble lubricant prior to insertion.Do not use petroleum-based products as they may be harmful to the respiratory tract.5.Reflux of gastric contents into the blue vent lumen indicates that the suction lumen is obstructed or suction is too low.Routinely check for reflux in the blue vent lumen and clear as per applicable directions.Failure to clear the obstruction or clear prevent® filter may cause gas and fluid buildup in stomach, aspiration of gastric contents, aspiration pneumonia and other complications.6.Do not inject fluid through the prevent® filter as this may result in blockage and leakage of filter.7.Monitor patient for nasal erosion, sinusitis, esophagitis, esophagotracheal fistula, gastric erosion and pulmonary & oral infections." section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BARD® NASOGASTRIC SUMP TUBE WITH PREVENT® ANTI-REFLUX FILTER
Type of Device
NG TUBE
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key8585937
MDR Text Key144268271
Report Number1018233-2019-02333
Device Sequence Number1
Product Code FEG
UDI-Device Identifier00801741052323
UDI-Public(01)00801741052323
Combination Product (y/n)N
PMA/PMN Number
K960176
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other,user facility
Type of Report Initial,Followup
Report Date 06/05/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/07/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date12/31/2023
Device Model Number0046160
Device Catalogue Number0046160
Device Lot NumberNGCZ2257
Was Device Available for Evaluation? No
Date Manufacturer Received05/20/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Age54 YR
Patient Weight92
-
-