Model Number CA15L2
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Codes Radiation Exposure, Unintended (3164); Device Embedded In Tissue or Plaque (3165)
Date of Event 04/17/2019
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
According to the reporter, during ablation, the ceramic tip disassembled and remained in the liver.No track ablation could be performed.Tip could not be removed.
 
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
According to the reporter, during ablation, the antenna was able to ablate tissue.But when physician moved it back the ceramic tip left in place(remained in the liver) and disassembled and remained in the liver.Tip could not be removed.With second antenna all steps were performed inclusively track ablation.Ct scan was performed for the ceramic tip that has left in the liver on an unproblematic position which from of physicians decided did not require resection.No further information available at this time.
 
Additional Manufacturer Narrative
Evaluation summary: one device was received for evaluation.Visual inspection found the ceramic tip is missing from the device.The tip was not returned.The customer reported that the ceramic tip broke off.The reported condition was confirmed.The investigation found the ceramic tip was missing on the returned device.The investigation could not determine the root cause of the customer's report.Corrective actions have been implemented to mitigate this issue.If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
Evaluation summary: one device was received for evaluation.The returned product did not meet specification as received.Visual inspection found the ceramic tip was missing from the tip of the antenna.No other anomalies of the device were noted.Evidence of sufficient adhesive application was observed.The reported condition was confirmed.The investigation included evaluation of additional information about the procedure.In the procedure in question, it was reported that an ultrasound needle guide (accessory device) was used.An instructions for use (ifu) update which included warnings related to use of accessory devices and additional use steps.During the subject procedure, the warnings and additional use steps were not followed by the user.The root cause could not be definitively determined; however, the most likely cause for the tip detachment was the warnings and additional use steps included in the ifu update not being followed.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EMPRINT
Common Device Name
SYSTEM, ABLATION, MICROWAVE AND ACCESSORIES
Manufacturer (Section D)
COVIDIEN MEDICAL PRODUCTS
building 10- no 789 puxing roa
shanghai 20111 4
CN  201114
MDR Report Key8596950
Report Number3006451981-2019-00083
Device Sequence Number2340162
Product Code NEY
UDI-Device Identifier10884521706583
UDI-Public10884521706583
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K163105
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 12/17/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/15/2020
Device Model NumberCA15L2
Device Catalogue NumberCA15L2
Device Lot NumberS8DG024X
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/18/2019
Initial Date Received by Manufacturer 04/18/2019
Supplement Date Received by Manufacturer09/02/2019
10/16/2019
12/05/2019
Initial Report FDA Received Date05/09/2019
Supplement Report FDA Received Date09/26/2019
11/07/2019
12/17/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age62 YR
-
-