• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDACTA INTERNATIONAL SA MYSPINE STANDARD DRILL GUIDE T07; SURGICAL INSTRUMENT FOR SPINE SURGERY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDACTA INTERNATIONAL SA MYSPINE STANDARD DRILL GUIDE T07; SURGICAL INSTRUMENT FOR SPINE SURGERY Back to Search Results
Catalog Number 7.0107
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 04/10/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Batch review performed on 06 may 2019: lot 01443s: (b)(4) items manufactured and released on 03-apr-2019.Expiration date: 2019-09-06.No anomalies found related to the problem.Clinical evaluation performed by medical affairs director: according to the report, the surgery has been delayed due to additional preparation required in order to position the guides.This was caused by deformity and thoracic dimensions that could not be taken into consideration at the time of guide planning.The surgery was completed with the use of the guides.The guides were manufactured as custom made devices according to the specifications of the prescription issued by the surgeon; no unconformity to the prescription could be identified.Hence, the surgical delay, deemed not critical by the surgeon, was not caused by a defect of the device.Mysolution department analysis: it is confirmed that there was a costal interference between the myspine standard guides from t07 to t10 and the patient's ribs.As per procedure in force the interference control is not performed between standard myspine guides and ribs.Additional instrument involved (k132788): 7.0108 myspine drill guide t08, lot: 01443s; 7.0109 myspine drill guide t089, lot: 01443s; 7.0110 myspine drill guide t10, lot: 01443s.
 
Event or Problem Description
Standard myspine guides from t7 to t10 didn't fit well with the corresponding vertebrae in situ due to costal interference.The surgeon had to prepare also the thoracic costotransverse joint in order to apply the guide.Some material was removed from the ribs to allow the use of the guides.The surgery was completed successfully with a delay of 20 minutes considered as not critical by the medical staff.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MYSPINE STANDARD DRILL GUIDE T07
Common Device Name
SURGICAL INSTRUMENT FOR SPINE SURGERY
Manufacturer (Section D)
MEDACTA INTERNATIONAL SA
strada regina
castel san pietro, 6874
SZ  6874
MDR Report Key8599632
Report Number3005180920-2019-00356
Device Sequence Number2339674
Product Code MNI
UDI-Device Identifier07630030856556
UDI-Public07630030856556
Combination Product (Y/N)N
Initial Reporter CountryIT
PMA/510(K) Number
K132788
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 05/10/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/06/2019
Device Catalogue Number7.0107
Device Lot Number01443S
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/10/2019
Initial Report FDA Received Date05/10/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age13 YR
Patient Weight55
-
-