• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COOK INC UNIVERSA FIRM URETERAL STENT SET; FAD STENT, URETERAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK INC UNIVERSA FIRM URETERAL STENT SET; FAD STENT, URETERAL Back to Search Results
Model Number G23405
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Code Available (3191)
Date of Event 04/19/2019
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Concomitant medical products: cook standard guide wire, sensor guide wire (boston scientific).(b)(6).(b)(4).This report includes information known at this time.A follow up report will be submitted should additional relevant information become available.
 
Event or Problem Description
It is reported a universa firm ureteral stent set was placed (b)(6) 2018.On (b)(6) 2019, the stent was removed.The stent was totally encrusted and very difficult to remove, extending operating time.The stent was being changed due to the patient's complex medical history.No additional consequences to the patient have been reported as occurring.Additional details regarding the patient and the event have been requested.At this time, no further information has been provided.
 
Additional Manufacturer Narrative
Blank fields on this form indicate the information is unchanged, unknown or unavailable additional information: d10.Investigation evaluation: reviews of complaint history, device history record, manufacturing instructions, quality control data and the instructions for use(ifu) were conducted during the investigation.The complaint device was not returned; therefore, no physical examinations could be performed.However, a document based investigation evaluation was performed.There is no evidence to suggest the product was not made to specifications.A review of the device history record found no non-conformances related to the reported failure mode.A review of complaint history records shows no other complaints associated with the complaint device lot.The instructions for use (ifu), provides the following information to the user related to the reported failure mode: "the universa® firm stents must not remain indwelling more than twelve (12) months.The universa® soft stents must not remain indwelling more than six (6) months.If the patient¿s status permits, the stent may be replaced with a new stent." "these stents are not intended as permanent indwelling devices." "tether should be removed if stent is to remain indwelling longer than 14 days." "do not force components during removal or replacement.Carefully remove the components if any resistance is encountered." "individual variations of interaction between stents and the urinary system are unpredictable." "periodic evaluation via cystoscopic, radiographic, or ultrasonic means is suggested.The stent must be replaced if encrustation hampers drainage." the device is supplied with instructions for use which includes cautions which refer to monitoring for stent encrustation and that individual variations of interaction between stents and the urinary system are unpredictable.A clinical assessment of the complaint was carried out which concluded, the most probable contributing factor is human anatomy related.The clinical specialist also stated the fact that stents are in the urinary tract already predisposes the device to urine¿s elements.Ureteral stent encrustation is a known inherent risk of the device.The rate and severity of encrustation is influenced by many factors.The cause of the complaint is attributable to encrustation a known inherent risk of the device.The complaint was confirmed based on the customers testimony.A review of production processes, quality inspection documentation and the device history records did not observe any specific issues with current manufacturing or quality controls that may have contributed to this incident.The risk analysis for this failure mode was reviewed, and it was determined that no additional risk mitigating activity is required.We will continue our monitoring of similar complaints and have notified the appropriate personnel of this event.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Event or Problem Description
There is no new patient or event information to report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNIVERSA FIRM URETERAL STENT SET
Common Device Name
FAD STENT, URETERAL
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key8609397
Report Number1820334-2019-01050
Device Sequence Number2339516
Product Code FAD
UDI-Device Identifier10827002234052
UDI-Public(01)10827002234052(17)210821(10)9109280
Combination Product (Y/N)N
Initial Reporter CountryGB
PMA/510(K) Number
K961446
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2019
Reporter Type Manufacturer
Report Source foreign,other,user facility
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 08/19/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date08/21/2021
Device Model NumberG23405
Device Catalogue NumberUFH-624-RT1
Device Lot Number9109280
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 04/29/2019
Supplement Date Received by Manufacturer07/30/2019
Initial Report FDA Received Date05/14/2019
Supplement Report FDA Received Date08/19/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age64 YR
Patient Weight126
-
-