| Catalog Number |
M8807 |
| Medical Device Problem Code |
Material Separation (1562)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
04/18/2019
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(4).Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Additional information was requested and the following was obtained: specific number of devices with needle pull off in this procedure.The instrumentalist opened a dozen packs each containing 5 needles of which 3 out of 5 were defective.How was case completed? the case was completed with the same device but belonging to a different lot.How long was the procedure delayed due to this issue? the delay on the procedure is not quantifiable but has resulted in an increase during aortic clamping were there any unexpected outcomes or complications as a result of the prolonged surgery time? there were no unexpected outcomes or complications was the patient treatment altered in anyway due to the prolonged surgery time? if yes, please explain.The patient's treatment has not been altered.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Please confirm if the device(s) will be returned.
|
| |
|
Event or Problem Description
|
|
It was reported that a patient underwent an unknown procedure on (b)(6) 2019 and suture was used.During the procedure, the needle detached from the suture without exerting traction.The event led to an increase in the duration of the intervention during aortic clamping.The patient's treatment had not been altered.There were no adverse patient consequences reported.The case was completed with the same device but belonging to a different lot.No additional information was provided.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).Date sent to the fda: 09/16/2019.A manufacturing record evaluation was performed for the finished device lot, and no non-conformances were identified.Additional h3: it was reported that the device had performance pull off suture needle.It was received for analysis an opened sample of product code m8807, lot meb993.The complaint sample was not received for evaluation.During the visual inspection of the sample, the swage and attachment area were noted to be as expected.The suture was dispensed without problems and examined along of the strand and no defects were observed.A functional test was performed and the pull force was above the minimum requirements.The manufacturing records were reviewed, and the manufacturing/packaging criteria were met prior to the release of this batch.Per the condition of the sample, no performance pull off suture needle was found, and the tested samples met the finished goods requirements.
|
| |
|
Search Alerts/Recalls
|