| Catalog Number |
866024 |
| Medical Device Problem Codes |
Loss of or Failure to Bond (1068); Malposition of Device (2616)
|
| Health Effect - Clinical Codes |
Unspecified Infection (1930); Pain (1994); Swelling (2091); Osteolysis (2377); No Code Available (3191)
|
| Date of Event |
01/31/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
(b)(6).Dots.Clinical notification received for the right knee revision that occurred on (b)(6) 2017, for aseptic tibial tray implant loosening.Right knee revision for failed fixation.Aseptic tibial tray loosening at the implant to cement interface, osteomyelitis, osteolysis.
|
| |
|
Additional Manufacturer Narrative
|
|
This product is already reported on (b)(4) and (b)(4).1818910-2019-93955, is being retracted as it is a report duplication.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report. if information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Additional narrative: product complaint # (b)(4).Investigation summary no device associated with this report was received for examination.Depuy synthes considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation may be re-opened as necessary.If information is obtained that was not available for the initial medwatch, a follow-up medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|