Model Number 9735602
Medical Device Problem Code Imprecision (1307)
Health Effect - Clinical Code Hematoma (1884)
Date of Event 04/24/2019
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Medtronic received information regarding a navigation system.It was reported that after a fess procedure, the anesthesiologist in the room noticed that there was swelling around the patient's left eye.The surgeon came back into the room and used navigation with an endoscope to confirm that the patient had an orbital hematoma.The ent blade was used during the procedure with the microdebrider, but the surgeon stated the backside of the instrument was facing anterior while navigating (the blade was lateral with the cutting side facing away from the orbit), therefore it cannot be confirmed what exactly occurred to cause the hematoma.The surgeon did further dissection and inserted a drain.After the drain was placed, the swelling immediately started going down.There was a delay to the procedure of less than one hour.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FUSION COMPACT
Common Device Name
EAR, NOSE AND THROAT STEREOTAXIC INSTRUMENT
Manufacturer (Section D)
MEDTRONIC NAVIGATION, INC
826 coal creek circle
louisville CO 80027
MDR Report Key8624771
Report Number1723170-2019-02484
Device Sequence Number2292597
Product Code PGW
UDI-Device Identifier00643169672956
UDI-Public00643169672956
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K153247
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 05/20/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number9735602
Device Catalogue Number9735602
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/24/2019
Initial Report FDA Received Date05/20/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age66 YR
Patient Weight75
-
-