• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 CWS 400ML EVACUATOR KIT WITH 1/8" (3.2MM 10 FR.) SILICONE ROUND DRAIN; WOUND DRAIN

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 CWS 400ML EVACUATOR KIT WITH 1/8" (3.2MM 10 FR.) SILICONE ROUND DRAIN; WOUND DRAIN Back to Search Results
Catalog Number 0043660
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.
 
Event or Problem Description
It was reported that the hemovac wound drain tubing disconnected from the device.No patient impact reported.
 
Event or Problem Description
It was reported that the hemovac wound drain tubing disconnected from the device.No patient impact reported.
 
Additional Manufacturer Narrative
The reported event was confirmed as cause unknown.Visual evaluation of the returned sample noted one opened (without original packaging), used 3-spring evacuator with drain tube and y-connector attached, with tape around the drain tube and 90 degree port on evacuator (cm7600100).Visual inspection of the sample noted no obvious visible defects.Force applied and the drain tube disconnected from 90 degree port on evacuator.This product is out of specification as per the standard which states the following, "verify drainage tube assembly/port.(this consists to assembly the tube to the port and verifies that this assembly must be the adequate)".Although the reported event was confirmed, the root cause could not be determined.A potential root cause for this failure could be " dimensions of suction port (port a) not to specification".The lot number is unknown therefore the device history record could not be reviewed.The instructions for use were found adequate and state the following: ¿iv.Precautions: 1.Ensure that the wound site is dry and free of debris before closure.2.The surgeon must determine the number of drains needed for an effective drainage of the entire wound site.3.The junction between the tubing and tissue at the drain entrance site must be air-tight for effective functioning of the system.4.If the drain is occluded, irrigation and/or aspiration of the drain may be required.5.The quality and quantity of drained fluid must be regularly monitored and reported to the surgeon.6.Reservoir, once full, must be emptied per hospital protocols.Failure to do so will result in incomplete drainage.7.Suction must be discontinued prior to the removal of the drain.8.Before starting the drainage procedure, ensure that all the connections are tight and free of any obstructions within the drainage pathway.Connections to check are: i) drain to suction source.Ii) y-connector (when applicable): ¿ drain to y-connector.¿ y-connector to suction source.9.Di(2-ethylhexyl) phthalate (dehp) is a plasticizer used in some polyvinyl chloride medical devices.Dehp has been shown to produce a range of adverse effects in experimental animals, notably liver toxicity and testicular atrophy.Although the toxic and carcinogenic effects of dehp have been well established in experimental animals, the ability of this compound to produce adverse effects in humans is controversial.There is no evidence that neonates, infants, pregnant and breast feeding women exposed to dehp experience any related adverse effects.However, a lack of evidence of causation between dehp-pvc and any disease or adverse effect does not mean that there are no risks.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CWS 400ML EVACUATOR KIT WITH 1/8" (3.2MM 10 FR.) SILICONE ROUND DRAIN
Common Device Name
WOUND DRAIN
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key8630673
Report Number1018233-2019-02673
Device Sequence Number1655127
Product Code GCY
UDI-Device Identifier00801741049392
UDI-Public(01)00801741049392
Combination Product (Y/N)N
Initial Reporter StateCO
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source other,user facility
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 07/17/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number0043660
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/15/2019
Initial Date Received by Manufacturer 05/01/2019
Supplement Date Received by Manufacturer06/26/2019
Initial Report FDA Received Date05/22/2019
Supplement Report FDA Received Date07/17/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-