STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON CR X3 TIBIAL INSERT; PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO
|
Back to Search Results |
|
| Catalog Number |
5530-G-509 |
| Medical Device Problem Codes |
Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Codes |
Injury (2348); Insufficient Information (4580)
|
| Date of Event |
04/18/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The following devices were also listed in this report: triathlon asymmetric x3 patella; cat# 5551-g-320; lot# 0y94; triathlon prim cem fxd bplt #5; cat# 5520b500; lot# stehf; triathlon cr fem comp #4 l-cem; cat# 5510f401; lot# stdlb.It cannot be determined which, if any of these devices may have caused or contributed to the patient's experience.Review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.There have been no other similar events for the lot referenced.It was noted that the device is not available for evaluation.Should additional information become available, it will be provided in a supplemental report upon completion of the investigation.The information in this report was provided by stryker orthopaedics legal affairs department.No additional information is available at this time due to the ongoing litigation.Should additional information become available, the evaluation summary will be submitted in a supplemental report.Device not returned.
|
| |
|
Event or Problem Description
|
|
It was reported through the communication of an attorney that allegedly the patient was revised due to "status post left tkr with prosthetic joint implant failure".
|
| |
|
Additional Manufacturer Narrative
|
|
An event regarding revision surgery involving a triathlon insert was reported.The event was not confirmed.Method & results: -device evaluation and results: not performed as product was not returned.-clinician review: a review of medical records indicated "root cause analysis: the cause of this event cannot be determined with certainty with the information provided.The reason stated for revision of the primary implant was due to "status post left tkr with prosthetic joint implant failure.".This is a nebulous and imprecise diagnosis.The term "implant failure" is often used to describe simple failure of a total knee arthroplasty due to myriad causes including infection, instability, loosening, impingement, etc.In most cases this does not relate to actual mechanical failure of the implant such as breakage.Therefore it is impossible to assign any causality to the implant with this imprecise diagnosis." -device history review: all devices were manufactured and accepted into final stock with no relevant reported discrepancies.-complaint history review: there have been no other similar events for the reported lot.Conclusion: a review of medical records indicated "root cause analysis: the cause of this event cannot be determined with certainty with the information provided.The reason stated for revision of the primary implant was due to "status post left tkr with prosthetic joint implant failure.".This is a nebulous and imprecise diagnosis.The term "implant failure" is often used to describe simple failure of a total knee arthroplasty due to myriad causes including infection, instability, loosening, impingement, etc.In most cases this does not relate to actual mechanical failure of the implant such as breakage.Therefore it is impossible to assign any causality to the implant with this imprecise diagnosis." the exact cause of the event could not be determined because insufficient information was provided.Additional information including operative reports, progress notes, x-rays and return of the device are needed to fully investigate the event.If further information becomes available or the product is returned, this investigation will be re-opened.
|
| |
|
Event or Problem Description
|
|
No new information.
|
| |
|