BOSTON SCIENTIFIC CORPORATION SYMMETRY STIFF SHAFT; CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL Back to Search Results
Model Number 23335
Medical Device Problem Code Material Rupture (1546)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 05/08/2019
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that balloon rupture occurred.The 90% stenosed target lesion was located in a shunt in the moderately tortuous and severely calcified arteriovenous fistula.A 3.5-10/4t/90 symmetry stiff shaft balloon catheter was advanced for pre-dilatation.However, on initial inflation at nearly 10 atmospheres for 10 seconds, the balloon ruptured.Since the lesion area was not completely dilated, pre-dilatation was performed again with another 3.5 x 4 symmetry balloon and the procedure was completed.There were no patient complications reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYMMETRY STIFF SHAFT
Common Device Name
CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key8643020
Report Number2134265-2019-05856
Device Sequence Number14028231
Product Code LIT
UDI-Device Identifier08714729182665
UDI-Public08714729182665
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K060959
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 05/25/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/28/2021
Device Model Number23335
Device Catalogue Number23335
Device Lot Number0021928470
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/08/2019
Initial Report FDA Received Date05/25/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-