| Model Number |
G34281 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Codes |
Foreign Body In Patient (2687); No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
04/29/2019
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Pma/510(k) #k160229.Cook ireland ltd (manufacturer) is submitting this report on behalf of cook medical incorporated (cmi)(importer).Exemption number: e2016031.Information pertaining to section g.1 as follows: importer site contact and address: (b)(4) cook medical incorporated (cmi) 1025 acuff road p.O box 4195 bloomington indiana 47402-4195.Importer site establishment registration number: 3005580113.Investigation is still pending.A follow up mdr will be submitted to include the investigation conclusions.
|
| |
|
Event or Problem Description
|
|
As reported to customer relations: "tip of the needle broke." dm unsure at time of initial reporting how much broke off, how many pieces, if any remains in patient, at what point of procedure the break occurred, if the patient has been harmed, or any other details.
|
| |
|
Additional Manufacturer Narrative
|
|
Pma/510(k) #k160229.Cook ireland ltd (manufacturer) is submitting this report on behalf of cook medical incorporated (cmi)(importer).Exemption number: e2016031.Information pertaining to section g.1 as follows: importer site contact and address: ed sutkowski cook medical incorporated (cmi) 1025 acuff road p.O box 4195 bloomington indiana 47402-4195.Importer site establishment registration number: 3005580113.1 unit of lot c1547037 of echo-hd-22-ebus-o-c was returned opened in its original packaging the device related to this occurrence underwent a laboratory evaluation.The needle was found to be broken.Prior to distribution, all echo-hd-22-ebus-o-c devices are subjected to functional checks and visual inspection to ensure device integrity.These inspections and functional checks are outlined in internal procedures in place at cirl.A review of the manufacturing records for echo-hd-22-ebus-o-c of lot number c1547037 did not reveal any discrepancies that could have contributed to this complaint issue.The review of relevant manufacturing records, confirms the failure mode has not previously occurred with the current lot number.Based on the information available to date, there is no evidence to suggest that there are any manufacturing issues associated with lot number c1547037.The notes section of the instructions for use, which accompanies this device instructs the user to; "visually inspect with particular attention to kinks, bends and breaks.If an abnormality is detected that would prohibit proper working condition, do not use" and ¿this device is intended for use with an olympus ebus scope." clarification was requested as to the type of scope used and it was confirmed that a fuji eb-530us scope was used.As this did not meet the ifu requirement a new pr was requested to be opened.There is no evidence to suggest that the customer did not follow the instructions for use.The failure of needle broken was observed in the laboratory.A definitive root cause for the customer complaint could not be determined as circumstances of use cannot be replicated in the laboratory.A possible root cause could be attributed to the device being used in a flexed or twisted position as indicated in the additional information.Complaint is confirmed as the failure was verified in the laboratory.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.Complaints of this nature will continue to be monitored for potential emerging trends.
|
| |
|
Event or Problem Description
|
|
As reported to customer relations: "tip of the needle broke." dm unsure at time of initial reporting how much broke off, how many pieces, if any remains in patient, at what point of procedure the break occurred, if the patient has been harmed or any other details.
|
| |
|
Search Alerts/Recalls
|