| Catalog Number |
365963 |
| Medical Device Problem Code |
Incorrect, Inadequate or Imprecise Result or Readings (1535)
|
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
05/29/2019
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Date of event: unknown.The date received by manufacturer has been used for this field.A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
|
| |
|
Event or Problem Description
|
|
It was reported that tubes were not clotting after use with a bd microtainer® z (no additive tubes).The following information was provided by the initial reporter: material no: 365963.Batch no:8155792.(1 of 2).It was reported the customer was experiencing tubes not clotting.Found out about the recall after experiencing issues.This has been occurring for a couple weeks, no specific dates known.
|
| |
|
Event or Problem Description
|
|
It was reported that tubes were not clotting after use with a bd microtainer® z (no additive tubes).The following information was provided by the initial reporter: material no: 365963 batch no:8155792 (1 of 2).It was reported the customer was experiencing tubes not clotting.Found out about the recall after experiencing issues.This has been occurring for a couple weeks, no specific dates known.
|
| |
|
Additional Manufacturer Narrative
|
|
H.6.Investigation summary: bd had not received samples or photos from the customer facility for evaluation; therefore, the investigation was limited.Retention samples were selected from bd inventory for evaluation/testing and upon completion, no issues were observed relating to samples not clotting, as all samples met specifications.A review of the device history record was completed for the incident lot and, based on this review, all product specifications and requirements for lot release were met; there were no related quality non-conformances during manufacturing of the product.Investigation conclusion: based on evaluation of the retain samples, the customer¿s indicated failure mode for samples not clotting with the incident lot was not observed as all samples met the required specifications.Root cause description: based on the investigation, a root cause could not be determined.The retain product was found to be in conformance and meet release specifications.Complaints received for this device and reported condition will continue to be tracked and trended.Information will be captured on trend reports and monitored.The bd business team regularly reviews the collected data for identification of emerging trends.H3 other text : see section h.10.
|
| |
|