B. BRAUN MELSUNGEN AG INTROCAN SAFETY®; CATHETER,INTRAVASCULAR,THE Back to Search Results
Model Number 4252520-02
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Codes Needle Stick/Puncture (2462); Blood Loss (2597)
Date of Event 05/23/2019
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).The investigation into this reported event is ongoing.Additional attempts to receive the sample are being made.A follow-up report will be submitted when the results of the investigation are available.
 
Event or Problem Description
As reported by user facility: immediately had blood coming out of puncture site.Attempted to aspirate blood and got air, able to hold down site and flush and aspirate blood.With second flush noted ns coming out of puncture site.
 
Additional Manufacturer Narrative
This report has been identified as b.Braun medical inc.Internal report number (b)(4).The actual device involved in the reported incident was not returned for evaluation.Without the actual sample a thorough sample analysis could not be performed and no specific conclusions can be drawn.No adverse quality trends of this nature were identified during the complaint review process for the reported catalog number.If additional pertinent information becomes available a follow-up report will be filed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INTROCAN SAFETY®
Common Device Name
CATHETER,INTRAVASCULAR,THE
Manufacturer (Section D)
B. BRAUN MELSUNGEN AG
carl-braun-str. 1
melsungen, 34212
GM  34212
MDR Report Key8699238
Report Number9610825-2019-00215
Device Sequence Number1935764
Product Code FOZ
UDI-Device Identifier04046963318178
UDI-Public(01)04046963318178
Combination Product (Y/N)N
Initial Reporter StateMN
Initial Reporter CountryUS
PMA/510(K) Number
K020785
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional,user faci
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 07/29/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number4252520-02
Device Catalogue Number4252520-02
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 05/30/2019
Supplement Date Received by Manufacturer05/30/2019
Initial Report FDA Received Date06/14/2019
Supplement Report FDA Received Date07/29/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No