Catalog Number UNK_SEL |
Device Problems
Fracture (1260); Device Dislodged or Dislocated (2923)
|
Patient Problems
Erythema (1840); Bone Fracture(s) (1870); Unspecified Infection (1930); Pain (1994); Swelling (2091); Joint Dislocation (2374); Ambulation Difficulties (2544); Fluid Discharge (2686)
|
Event Date 11/01/2012 |
Event Type
Injury
|
Manufacturer Narrative
|
The reported event could not be confirmed, since the device was not returned for evaluation and no other evidences were provided.This complaint has been reported during a literature review performed by the post market surveillance group.No product identification is possible.More detailed information about the complaint event as well as the affected device must be available in order to determine the root cause of the complaint event.The reviewed ifu, however, states that ¿early or late infection, both deep or superficial¿ is one of the most frequent adverse effects involving the use of internal fracture fixation devices and adverse results may be clinically related rather than device related.Also, the surgeon must warn patients of surgical risks, and make them aware of possible adverse effects.The patient should be warned that the device cannot and does not replicate a normal healthy bone, that the device can break or become damaged as a result of strenuous activity or trauma.Based on the available information, no relation could be established between the device and the reported event.A review of the labeling did not indicate any abnormalities.If any further information is provided, the investigation report will be updated.Device disposition unknown.
|
|
Event Description
|
The manufacturer became aware of a post market clinical follow-up (pmcf) from (b)(6).The title of this report is ¿a post-market clinical follow-up (pmcf) of the treatment of fractures with the apex pins in conjunction with stryker external fixation systems¿ which was published in april 2019 and is associated with the stryker apex pin.Within that publication, post-operative complications/ adverse events were reported, which occurred between november 2012 to september 2018.It was not possible to ascertain specific device or patient information from the article, a review of the complaint handling database, however, revealed that the events have not been reported by the hospital or by the author of the publication, therefore 52 complaints were initiated retrospectively for different adverse events mentioned in the journal.This product inquiry addresses pin tract infection.13 out of 15 cases.The report states, ¿subject a1-13 was a (b)(6) year old female (other race) who struck her ankle on an object at work and sustained a right pilon fracture (closed), right dislocated talus and right charcot ankle.A stryker external fixator with 4 apex pins was placed for definitive treatment.Her history was significant for a left medial malleolus (closed) which was her initial injury after striking her ankle at work approximately six weeks prior to seeking treatment.The left medial malleolus was treated non-operatively and subject returned to the emergency department 23 days later with increased pain and difficulty walking at which time the right pilon, fracture, dislocated talus and charcot ankle was diagnosed.Subject also has a history of diabetes.Discharged on pod 4, non-weightbearing.Subject followed up with podiatry who recommended an ankle fusion.Subject refused additional surgery.Subject presented to the emergency department approximately 3.5 months after ex-fix placement complaining of pain and swelling of right foot.Minimal erythema at pin insertions was noted.Subject was prescribed a two weeks course of antibiotics.Subject was seen in clinic 20 days later and erythema with drainage around the distal medial pin was noted.She was diagnosed with a pin tract infection.Ex-fix was also removed at this time (122 days after placement).Subject returned to the clinic one week later, the orthopaedist noted that ¿she had some discoloration but no expressible purulence and really no erythema around the area.¿ there was no additional documentation regarding the pin tract infection in the subject¿s other note.¿.
|
|
Search Alerts/Recalls
|
|