| Model Number |
N/A |
| Medical Device Problem Codes |
Fluid/Blood Leak (1250); Leak/Splash (1354); Material Separation (1562)
|
| Health Effect - Clinical Codes |
No Known Impact Or Consequence To Patient (2692); No Code Available (3191)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Occupation: unknown.Pma/510(k) #: pre-amendment.This report includes information known at this time.A follow up report will be submitted should additional relevant information become available.
|
| |
|
Event or Problem Description
|
|
It was reported a ultrathane cope nephroureterostomy set was used in a unknown patient for a drainage procedure.The user reports leaking at the hub after placement.The device was removed, and another similar device placed successfully.As reported, the patient did not experience any adverse effects or require any additional procedures due to this occurrence.
|
| |
|
Additional Manufacturer Narrative
|
|
Blank fields on this form indicate the information is unknown, unchanged or unavailable.Additional information: b1, b2, b5, h1, h6.B5 - event description: additional information was provided by the complaint facility on (b)(6) 2019.The device did not leak during the procedure.The patient found the device leaking while traveling home and the device was replaced the next day.The tube was also found snapped at the hub.It was noted the catheter fitting was securely connected to a gravity drainage bag.H6 - patient code: no code available (3191) - additional procedure required to replace device.H6 - device codes: leak and material separation included to reflect the leakage and "tube snapped at the hub." this report includes information known at this time.A follow up report will be submitted should additional relevant information become available.This report is required by the fda under 21 cfr part 803.This report is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement made in it is intended to be an admission that any cook device is defective or malfunctioned; that a death or serious injury occurred; or that any cook device caused or contributed to; or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|
| |
|
Event or Problem Description
|
|
See h10.
|
| |
|
Event or Problem Description
|
|
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
|
| |
|
Additional Manufacturer Narrative
|
|
Investigation - evaluation: a review of the complaint history, device history record, drawing, instructions for use (ifu), manufacturing instructions, quality control, and specifications of the device were conducted during the investigation.The complaint device was not returned; therefore, no physical examinations could be performed.However, a document based investigation evaluation was performed.The proper procedures are in place to identify and prevent this failure mode prior to device distribution.The risk specifications covering mac-loc drainage catheters include both hub separation and leakage as a potential failure mode.The identified risk controls include manufacturing quality control checks and process validation.The technical files covering mac-loc drainage catheters indicate that the risks associated with these devices are acceptable when weighed against the benefits.A review of the device history record (dhr) shows no nonconforming events which were related to the failure mode.A software search revealed no additional complaints for this lot number.As there are adequate inspection activities established, objective evidence that the dhr was fully executed, no related non-conformances, and no other lot related complaints from the field.It was concluded that there is no evidence that nonconforming product exists in house or in field based on the information provided, no returned product and the results of the investigation, a definitive cause could not be established.Appropriate measures have been taken to address this failure mode.The appropriate personnel have been notified.Cook will continue to monitor for similar complaints.Per the quality engineering risk assessment no further action is required.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|
| |
|
Search Alerts/Recalls
|