Catalog Number UNK_SEL |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problem
Numbness (2415)
|
Event Date 11/01/2012 |
Event Type
Injury
|
Manufacturer Narrative
|
The reported event could not be confirmed, since the device was not returned for evaluation and no other evidences were provided.This complaint has been reported during a literature review performed by the post market surveillance group.No product identification is possible.More detailed information about the complaint event as well as the affected device must be available in order to determine the root cause of the complaint event.The reviewed ifu, however, states that the deep venous thrombosis is one of the most frequent adverse effects involving the use of internal fracture fixation devices and adverse results may be clinically related rather than device related.Also, the surgeon must warn patients of surgical risks, and make them aware of possible adverse effects.The patient should be warned that the device cannot and does not replicate a normal healthy bone, that the device can break or become damaged as a result of strenuous activity or trauma.Based on the available information, no relation could be established between the device and the reported event.A review of the labeling did not indicate any abnormalities.If any further information is provided, the investigation report will be updated.Device evaluated by mfr: device disposition unknown.
|
|
Event Description
|
The manufacturer became aware of a post market clinical follow-up (pmcf) from (b)(6) medical campus ((b)(6)).The title of this report is ¿a post-market clinical follow-up (pmcf) of the treatment of fractures with the apex pins in conjunction with stryker external fixation systems¿ which was published in april 2019 and is associated with the stryker apex pin.Within that publication, post-operative complications/ adverse events were reported, which occurred between november 2012 to september 2018.It was not possible to ascertain specific device or patient information from the article; a review of the complaint handling database, however, revealed that the events have not been reported by the hospital or by the author of the publication.Therefore, 52 complaints were initiated retrospectively for different adverse events mentioned in the journal.This product inquiry addresses nerve lesion.The report states, ¿subject (b)(6) was a (b)(6) caucasian male who had a fall from standing injuring his left elbow (radial head fracture and elbow dislocation).Orif of the left elbow with radial head arthroplasty was performed and a stryker external fixator with four apex pins was placed for temporary stabilization.His history was significant for current tobacco use.Discharged on the same day as his surgery and placed non-weightbearing status.Subject was seen 10 days post op in the clinic and stated he developed an inability to use his left wrist, hand and fingers two to three days after surgery.Onset was gradual but complete.He also complained of numbness in the hand along the dorsal aspect of the thumb.Examination showed complete¿.
|
|
Search Alerts/Recalls
|
|