| Model Number |
M00558930 |
| Medical Device Problem Code |
Material Puncture/Hole (1504)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
06/03/2019
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(4).Although the suspect device has been received, the evaluation has not been completed.Therefore, the cause of the reported malfunction has not been determined.Upon completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental mdr will be filed.
|
| |
|
Event or Problem Description
|
|
It was reported to boston scientific corporation that a cre rx biliary dilatation balloon was used in the papilla during an endoscopic retrograde cholangiopancreatography (ercp) procedure performed on (b)(6) 2019.According to the complainant, during the procedure, while physician was performing sphincteroplasty, a small hole opened in the side of the balloon and water started to stream out causing the balloon to deflate.The procedure was completed with a different device.There have been no patient complications reported as a result of this event.The patient condition at the conclusion of the procedure was reported to be stable.
|
| |
|
Additional Manufacturer Narrative
|
|
Block h6: problem code 1504 captures the reportable event of balloon pinhole.Block h10: investigation results visual examination of the returned complaint device revealed the balloon did not show visual defects and looked normal.No damage found on the catheter of the device.Functional analysis was performed, and the balloon was inflated without a problem; however, balloon would not hold pressure due to a pinhole found over the ro marker.This failure is likely due to factors or conditions related to the procedure that could have affected its performance and its intended purpose such as; the manner the device was handled, and/or the interaction with the scope during the procedure.Therefore, the most probable root cause is adverse event related to procedure.A review of the device history record (dhr) was performed and confirmed that this device met all material, assembly and performance specifications.
|
| |
|
Event or Problem Description
|
|
It was reported to boston scientific corporation that a cre rx biliary dilatation balloon was used in the papilla during an endoscopic retrograde cholangiopancreatography (ercp) procedure performed on (b)(6) 2019.According to the complainant, during the procedure, while physician was performing sphincteroplasty, a small hole opened in the side of the balloon and water started to stream out causing the balloon to deflate.The procedure was completed with a different device.There have been no patient complications reported as a result of this event.The patient condition at the conclusion of the procedure was reported to be stable.
|
| |
|