Additional product code hwc.It is unknown if device will be returned.Reporter is company representative; no facility contact available.The investigation could not be completed; no conclusion could be drawn, as no product was received.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.No valid explant date; this was an intraoperative event no code available is for surgical/medical intervention device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Event : updated information provided for reporting.Exp date provided for reporting.A review of the device history.Device history lot manufacturing location: monument, manufacturing date: 31-oct-2007, expiration date: 01-sep-2016, part number: 456.401s, 11mm/125 deg ti cann troch fixation nail 400mm/left- sterile, lot number: 5360689 (sterile), lot quantity: 6.Work order traveler met all inspection acceptance criteria.Inspection sheet, in-process acceptance, 456ipa391 rev c met all inspection acceptance criteria.Inspection sheet, inspect dimensional, 456id390 rev r met all inspection acceptance criteria.Inspection sheet, final inspection, 456fi390 rev f met all inspection acceptance criteria.Packaging label log lppf, lmd/lpf rev g was reviewed and determined to be conforming.Packaging bom was reviewed and determined to be conforming with no deviations to normal packaging identified.Scn 4797 supplied by sterigenics was reviewed and determined to be conforming.This lot met all dimensional, visual, sterility and packaging criteria at the time of release with no issues documented during the manufacture that would contribute to this complaint condition.Component part(s) reviewed: 456.314.2, lock 125, bp55, lot number: 5536512, lot quantity: 210.Work order traveler met all inspection acceptance criteria.Inspection sheet, incoming inspection, 456fi314 rev k met all inspection acceptance criteria.Certificate of compliance supplied by mark two engineering dated (b)(6) 2007 was reviewed and determined to be conforming.456.314.3, lock driver tfn, bp55 lot number: 5536586, lot quantity: 210.Work order traveler met all inspection acceptance criteria.Inspection sheet, inspect dimensional / final, 456fi314-3 rev e met all inspection acceptance criteria.Part number: 21069, tialnbri18.00, bp80, lot number: 5172172, lot quantity: 3,678 lbs.Product traveler met all inspection acceptance criteria.Inspection sheet, raw material inspection, rmtialnbr118_00 rev h met all inspection acceptance criteria.Certificate of test supplied by allvac dated 07-jun-2007 was reviewed and determined to be conforming.Raw material receiving / putaway checklist met all inspection acceptance criteria.Device history batch null, device history review, this lot met all dimensional, visual, sterility and packaging criteria at the time of release with no issues documented during the manufacture that would contribute to this complaint condition.Investigation summary product was not returned.Based on the information available, it has been determined that no corrective and preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|