BOSTON SCIENTIFIC CORPORATION SYNERGY; BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM Back to Search Results
Model Number 10603
Device Problem Fracture (1260)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 06/05/2019
Event Type  malfunction  
Manufacturer Narrative
Device is a combination product.
 
Event Description
It was reported that stent fracture occurred.The >70% stenosed target lesion was located in the moderately tortuous and moderately calcified right coronary artery.A 4x20mm, 3x16mm, 3x20mm synergy drug-eluting stents were advanced for treatment.However, the stents struts were fractured.The procedures were completed with another synergy stents.No patient complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNERGY
Type of Device
BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC IRELAND LIMITED
ballybrit business park
galway
EI  
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key8749430
MDR Text Key149677337
Report Number2134265-2019-06930
Device Sequence Number1
Product Code NIQ
UDI-Device Identifier08714729840190
UDI-Public08714729840190
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P150003
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Other
Type of Report Initial
Report Date 07/01/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date11/20/2020
Device Model Number10603
Device Catalogue Number10603
Device Lot Number0023004574
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 06/10/2019
Initial Date FDA Received07/01/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured11/21/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-