Catalog Number 00880100100
Device Problem Failure to Cut (2587)
Patient Problem No Patient Involvement (2645)
Event Date 06/05/2019
Event Type  malfunction  
Manufacturer Narrative
This event has been recorded under zimmer biomet complaint number (b)(4).The device has been returned to the repair center for evaluation and investigation is in process.Once the investigation is completed, a supplemental report will be filed accordingly.
 
Event Description
It was reported that the device had an unknown issue in repair: it was found that the skin was taken not smoothly while testing.Event was discovered during kit inspection.No adverse events were reported as a result of this malfunction.
 
Manufacturer Narrative
This event has been recorded under zimmer biomet complaint number: (b)(4).The device history record for zimmer air dermatome serial number: (b)(6) was reviewed and noted no related non-conformances, requests for deviation (rfd), change notices (cn), or any other issues with the device.The record review found no issues with the device and all verifications, inspections, and tests were successfully completed.The reported event was confirmed by the service technician who performed the evaluation and repair.On 25 june 2019, it was reported that a dermatome not taking skin smoothly on (b)(6) 2019.The customer returned a zimmer air dermatome serial number: (b)(6) for evaluation.Evaluation of the device on 5 june 2019 noted that the dermatome was out of calibration at all four settings and that the motor did not run.Repair of the device occurred on 25 june 2019 and involved replacing the motor, multiple bearings, o-ring, and the reciprocating arm.The technician then tested and verified that the device was functioning as intended, then returned the device to the customer without further incident.The device was tested, inspected, and repaired.While the service technician found that the dermatome was out of calibration at all four settings, which would cause the device to not make a proper cut during use, it cannot be determined from the information provided as to what caused the device to fall out of calibration.As such, a specific root cause of the reported event cannot be determined.The investigation was based on the information that was provided initially and any information that was obtained throughout the follow-up process.Review of the information provided during the investigation determined that there are no further actions needed at this time.This complaint will be tracked and trended for any adverse trends that may warrant further action.
 
Event Description
No additional information available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ZIMMER AIR DERMATOME
Type of Device
DERMATOME
Manufacturer (Section D)
ZIMMER SURGICAL, INC.
200 west ohio avenue
dover OH 44622
MDR Report Key8800136
MDR Text Key151356764
Report Number0001526350-2019-00559
Device Sequence Number1
Product Code GFD
Combination Product (y/n)N
PMA/PMN Number
EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 10/10/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/17/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number00880100100
Device Lot Number62096297
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/25/2019
Was the Report Sent to FDA? No
Date Manufacturer Received10/09/2019
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberN/A
Patient Sequence Number1
-
-