| Model Number |
G31520 |
| Medical Device Problem Code |
Material Twisted/Bent (2981)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
06/27/2019
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Pma/510(k) #k083330.(b)(4).Exemption number: e2016031.(b)(4).Investigation is still pending.A follow up mdr will be submitted to include the investigation conclusions.
|
| |
|
Event or Problem Description
|
|
They checked that mass location was body of pancreas before the procedure in eus.They advanced echo-19 to mass in through the scope.However, the needle didn't puncture to mass in eus.Consequently, the needle was removed out of the scope.So they used competitor eus needle.(mediglobe 19g).
|
| |
|
Additional Manufacturer Narrative
|
|
Pma/510(k) #k083330.Cook ireland ltd (manufacturer) is submitting this report on behalf of cook medical incorporated (cmi)(importer).Exemption number: e2016031.Information pertaining to section g.1 as follows: importer site contact and address: (b)(4).Cook medical incorporated (cmi) 1025 acuff road p.O box 4195 bloomington indiana 47402-4195.Importer site establishment registration number: 3005580113.1 x echo-19 of lot # c1577215 was returned to cirl for evaluation open in its original packaging.With the information provided, a physical examination and document based investigation was conducted.The device related to this occurrence underwent a laboratory evaluation.The needle was found to be kinked distally.Additionally the needle was observed to be kinked below sheath extender.Therefore, following the laboratory evaluation additional complaint file was requested to capture this failure separately.Prior to distribution, all echo-19 devices are subjected to functional checks and visual inspection to ensure device integrity.These inspections and functional checks are outlined in internal procedures in place at cirl.A review of the manufacturing records for echo-19 of lot number c1577215 did not reveal any discrepancies that could have contributed to this complaint issue.The notes section of the instructions for use, which accompanies this device instructs the user to; "visually inspect with particular attention to kinks, bends and breaks.If an abnormality is detected that would prohibit proper working condition, do not use".There is no evidence to suggest that the customer did not follow the instructions for use.The failure of needle kinked/bent was observed in the laboratory.A definitive root cause for the customer complaint could not be determined as circumstances of use cannot be replicated in the laboratory.A possible root cause could be attributed to hard lesion, possibly causing the distal end of the needle to kink.Complaint is confirmed as the failure was verified in the laboratory.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.
|
| |
|
Event or Problem Description
|
|
They checked that mass location was body of pancreas before the procedure in eus.They advanced echo-19 to mass in through the scope.However, the needle didn't puncture to mass in eus.Consequently, the needle was removed out of the scope.So they used competitor eus needle.(mediglobe 19g).
|
| |
|