Catalog Number RTLR180343
Device Problem Overfill (2404)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 07/12/2019
Event Type  malfunction  
Manufacturer Narrative
The plant investigation is in process.A supplemental mdr will be submitted upon completion of this activity.
 
Event Description
This is a report of a patient who experienced an increased intraperitoneal volume (iipv) event coincident with peritoneal dialysis (pd) therapy.The event was discovered while reviewing the patient¿s treatment records following a report of power outage due to a storm.A review of the patient¿s treatment records identified that the patient drained 4005 ml during drain 0 of the treatment.This drain volume is 190% the patient's prescribed fill volume of 2000 ml.As a result of the iipv event, the technical support representative advised the patient to discontinue use of the cycler and to notify their peritoneal dialysis registered nurse (pdrn) of the event.Additional information was requested, however to date not provided.
 
Manufacturer Narrative
Plant investigation: the actual device was returned to the manufacturer for physical evaluation.An external visual inspection was performed with no physical damage noted.A simulated therapy was initiated and completed on the cycler without complication.The cycler did not power down during the treatment test.The weighed fill volumes were found to be within tolerance and fill times were within specification.The cycler underwent system air leak, voltage check and valve actuation testing and was found to meet product specifications.Load cell verification testing was performed with no issues noted.A review of the device manufacturing records was conducted by the manufacturer.There were no deviations or non-conformances during the manufacturing process.In addition, a device history record (dhr) review was performed and verified that the results of the in-progress and final quality control (qc) testing met all requirements.Upon completion of the evaluation, there were no malfunctions that could have caused or contributed to the reported event.The cycler performed as designed and an associated cause could not be determined.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LIBERTY SELECT CYCLER ASSY(NON-VALUATED)
Type of Device
SYSTEM, PERITONEAL, AUTOMATIC DELIVERY
Manufacturer (Section D)
CONCORD MANUFACTURING
4040 nelson avenue
concord CA 94520
MDR Report Key8837467
MDR Text Key152531159
Report Number2937457-2019-02346
Device Sequence Number1
Product Code FKX
UDI-Device Identifier00840861102068
UDI-Public00840861102068
Combination Product (y/n)N
PMA/PMN Number
K181108
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Type of Report Initial,Followup
Report Date 08/14/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Catalogue NumberRTLR180343
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/24/2019
Device Age MO
Initial Date Manufacturer Received 07/12/2019
Initial Date FDA Received07/29/2019
Supplement Dates Manufacturer Received08/02/2019
Supplement Dates FDA Received08/14/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
DELFLEX PD FLUID; LIBERTY CYCLER SET ; DELFLEX PD FLUID; LIBERTY CYCLER SET 
-
-