BOSTON SCIENTIFIC CORPORATION SYNERGY; BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM Back to Search Results
Model Number 10602
Device Problem Migration (4003)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 07/15/2019
Event Type  Injury  
Manufacturer Narrative
Device is a combination product.
 
Event Description
It was reported that stent migration occurred.The target lesion with a bend of 90 degrees and located in the circumflex artery.A 2.50 x 16 mm synergy drug-eluting stent was attempted to advance through an under-deployed stent that was implanted 3 months prior to this procedure.The synergy stent could not cross and the stent delivery system was pulled back into the guidezilla ii.The stent embolized inside the patient as it was being pulled back into the guidezilla ii.The physician placed a 2.5 x 20 mm synergy to cover the embolized stent.The procedure was completed by upsizing the guide extension catheter to a 7fr guidezilla ii and balloon dilations were performed.No further patient complications were reported and the patient was fine.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNERGY
Type of Device
BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC IRELAND LIMITED
ballybrit business park
galway
EI  
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key8846921
MDR Text Key152815577
Report Number2134265-2019-08939
Device Sequence Number1
Product Code NIQ
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P150003
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial
Report Date 07/31/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/31/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number10602
Device Catalogue Number10602
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received07/16/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-