• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ETHICON ENDO-SURGERY, LLC. PROXIMATE*HCS HEMORR CIR STAPL; STAPLE, IMPLANTABLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ETHICON ENDO-SURGERY, LLC. PROXIMATE*HCS HEMORR CIR STAPL; STAPLE, IMPLANTABLE Back to Search Results
Catalog Number PPH01
Health Effect - Clinical Codes Hematoma (1884); Incontinence (1928); Pain (1994); Blood Loss (2597); No Code Available (3191)
Date of Event 01/01/2006
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Date of event: publication year of 2006.Batch # unk.This report is related to a journal article; therefore, no product will be returned for analysis and the manufacturing records cannot be reviewed as the lot/batch number has not been provided.(b)(4).
 
Event or Problem Description
It was reported via literature entitled: stapled transanal rectal resection to treat obstructed defecation caused by rectal intussusception and rectocele.Author/s: a.Renzi, d.Izzo, g.Di sarno, g.Izzo, n.Di martino.Citation: int j colorectal dis (2006); 21: 661¿667.Doi 10.1007/s00384-005-0066-5.This study was designed to determine the safety and efficacy of a modified stapled transanal rectal resection (starr) in patients with obstructed defecation syndrome (ods) caused by rectal-intussusception (ri) and/or rectocele (re).All the patients who underwent starr for ods caused ri and/or re were prospectively introduced into a database.Between june 2002 and february 2004, 68 patients (3 male and 65 female; mean age: 48.8±13.4 years; age range: 23¿77) with ods were observed.The modified starr procedure proposed reproduces the surgical technique proposed by antonio longo even if some modifications were suggested.Two pph-01 kits (ethicon) were utilized.Reported complication included failed to appose metallic agraphes (n-1) in which a handmade suture was necessary to complete the retrorectal anastomosis.Early complications included mild perineal hematoma (n-16) and bleeding (n-2).Reported late complications (3-month follow up) included urge to defecate (n-3) which spontaneously resolved within 6 months, incontinence to flatus (n- 2) which spontaneously resolved within 6 months, dyspareunia (n-1) which spontaneously resolved within 6 months, and rectal stenosis (n-1) which successfully treated by a new circular stapler resection.In conclusion, the surgical technique seems to be safe and effective, with a successful outcome in about 90% of the patients.However, despite these encouraging results, randomized trials and a longer follow-up are required to confirm starr as a good choice in the surgical treatment of ods caused by re and/or ri.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Common Device Name
STAPLE, IMPLANTABLE
Manufacturer (Section D)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo 00969
MDR Report Key8859848
Report Number3005075853-2019-20920
Device Sequence Number1937956
Product Code GDW
UDI-Device Identifier10705036012993
UDI-Public10705036012993
Combination Product (Y/N)N
Initial Reporter CountryIT
PMA/510(K) Number
K030925
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign,literature
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 07/12/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue NumberPPH01
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 07/12/2019
Initial Report FDA Received Date08/05/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-